Instruction manual
Battery Back Up Installation
Step 19 -Battery Back Up (optional)
The opener has provision for a Battery Back Up kit that
allows continued operation of the door in the absence of
mains power.
Step 19.1 -Installation
Disconnect power to the opener.
Remove screws and swing the cover open (Fig. 39).
Use battery pack # 1. Mount battery pack and secure
with item 11 and 13.
Mount the pcb support item16 on to chassis with item
12 and install the SBY-3 item 8 Charger Board on to
the pcb support with item 14 screws.
Feed the 2-wire battery harness item 10, through the
grommet on the base plate and connect to the SBY-
3.
Feed the charger harness from SBY-3 to the control
board. Plug the 4-pin connector marked “SBY-3”
onto the control board.
Warning: After the next step the opener may
become active (even when power is off) due to
a residual charge in the batteries.
1.
2.
3.
4.
5.
6.
7. Connect item 5 and 10 together (Fig 39).
8. Reconnect the power.
Step 19.2 -Testing Battery Back Up
Press either the OPERATE button or transmitter
to activate the opener.
Whilst the door is in motion disconnect mains
power - the opener should continue to operate.
Note: Wait for the door to complete its
travel before proceeding to the next step
Press either the OPERATE button or transmitter
to activate the opener.
Whilst the door is in motion re-connect power.
The door should complete the cycle as normal.
Step 19.3 -Troubleshooting
If door stops or moves very slowly under battery power,
then the batteries may have little to no charge.
To remedy this connect mains power and leave the
batteries to charge. The batteries may take 24 to 48
1.
2.
3.
4.
Fig. 39
D Power Drive : Instruction Manual
© Copyright 2009 B&D Doors
21Controll-A-Door
®
S
Instruction Manual