Instruction manual

Parameters
Door status indicators
Door opener state OPEN LED (green) CLOSE LED (red) Beeper
Open On
Close On
Opening Flashing
Closing Flashing
Door travel stopped Flashing Flashing
Door obstructed when opening Flashing
Door obstructed when closing Flashing Beeps while door is
moving
Opener overloaded Alternating ashes Alternating ashes
Mains power interrupted Rapid ashes
Button Function
OPERATE Opens/stops/closes the door
DOOR CODE Codes a transmitter button for operate function
FORCE MARGIN SET & PLUS (+) Increases the obstruction force margin setting
FORCE MARGIN SET & MINUS (-) Decreases the obstruction force margin setting
FORCE MARGIN SET (then) SET Reloads the factory set default obstruction force margin setting
(-) (for 6 seconds) Clears the door limits set positions. Limits then need to be reset
SET (the power on) and hold until all
LEDs are off
Deletes control parameters excluding transmitter storage memory
DOOR CODE press and hold until
DOOR CODE LED starts ashing
Deletes all transmitter storage memory
SET & DOOR CODE (the power on)
and hold until all LEDs are off
Deletes all control parameters and transmitter storage memory
Controll-A-Door
®
S