Instruction manual
Default Settings & Specifi cations
Factory default settings
Default Step Minimum Maximum
Courtesy light time 3 minutes
10 Sec in battery
backup mode
- 3 minutes
10 Sec in battery
backup mode-
3 minutes
10 Sec in battery
backup mode-
Obstruction force margin 0.7 amps 0.1 amps 0 2.0 amps
Technical specifi cations
Power supply 230V - 240Va.c. 50Hz
Transformer rating 24Vd.c.
Standby power 2.2 Watts
Motor power 100 Watts
Motor type 24Vd.c permanent magnet
Shuttle travel distance in the C-Rail 2.7m approx. (standard)*
Maximum shuttle travel distance in the C-Rail 3.750 m (with one extension)*
Maximum door opening: Width:
Height:
Weight:
5500mm (16.5m
2
)
2150mm
100kg
Minimum headroom 25mm
Short term peak force 700N (70kg)
Lift force 450N (45kg)
Nominal force 150N (15kg)
Receiver type UHF Multi-frequency FM Receiver
Receiver code storage capacity 8 X 4 button Transmitter Codes
Transmitter frequency 433.47, 433.92, 434.37 MHz
Coding type Tri-Tran™
Number of code combinations Over 4.29 billion random codes
Code generation Non-linear encryption algorithm
Transmitter battery CR2032 (3 Volts)
Courtesy light Festoon style lamp 24 volts 15 watt
Controller fuse 10A slow blow
*The actual travel of the door depends on confi guration of the connecting arms.
Note: Intermittent operations may occur in areas which experience very strong winds. The strong wind puts extra pressure
on the door and tracks which may in turn intermittently trigger the safety obstruction detection system.
Controll-A-Door
®
S
Instruction Manual4