Instruction manual
Operating Controls
Terminal Block:
24V PWR is used to power devices such as Safety Infra-red Beams and external receiver (100 milliamp max).
P.E(IR) input is used to connect to Safety Infra-red Beam.
P.E(IR) 0V is a 0 volt connection for Safety Infra-red Beam.
GND is a common -ve ground for accessories
OSC is used for the connection of a wired switch (momentary contact). This switch can then be used to open, stop
or close the door. Install the wall switch in a location where the switch is out of reach of children and the garage door
is visible.
AUX OUT This function allows the opener to operate other devices such as external lights, or an alarm system.
CODING LED
(red) light fl ashes when a code is being stored or when a transmitter button is pressed.
DOOR CODE button is used for storing or erasing transmitter buttons for door operation
SERVICE LED (Yellow) indicates when the opener requires service or repairs.
SET button (Orange) is used during the installation phase together with the Open and MINUS (-) buttons to set the door
limit positions. The Set button is also used to re-initialize the Opener.
OPERATE button (Yellow) is used during installation to test the open, stop and close cycles for the opener. The opener
has to be initialised by the SET button to make the OPERATE button operable.
FORCE MARGIN SET
Button: The obstruction force margin is set automatically during installation. The margin can be
adjusted manually using the Force Margin Set button (White). Holding the Force Margin Set button and pressing PLUS
(+) or MINUS (-) buttons will increase or decrease the amount of force. The Force Margin Set should only be used if
environmental factors (wind, etc.) affect the door’s operation.
OPEN LIMIT LED (green) the LED is very helpful during installation. It illuminates and fl ashes when the door is opening
and remains steady on when the open limit position has been reached.
PLUS (+) button (green) is used during installation to help set the open limit position. Pressing and holding this button
will move the door in the open direction, releasing stops the door.
NOTE: The safety obstruction detection is inoperable when the PLUS (+) button is used to move door.
CLOSE LIMIT LED (red) the LED is very helpful during installation. It illuminates and fl ashes when the door is closing
and remains steady on when the close limit position has been reached.
MINUS
(-) button (red) is used during installation to help set the close limit position. Pressing and holding this button
will move the door in the close direction. Movement stops when the button is released.
NOTE: The safety obstruction detection is inoperable when the CLOSE button is used to move door.
DATUM ADJUST SCREW is used during limits set up to indicate the mid point of the door’s travel.
10A FUSE
PROG INPUT is used to connect the Handheld “PG-3” Programmer for editing control and receiver functions, accessing
diagnostic tools, and activating special features and operating modes.
JP1 SOLAR CONNECTOR
the shunt must be fi tted for solar operation.
COURTESY LIGHT 15 watts 24 volts festoon type globe is used for courtesy light
01.
02.
03.
04.
05.
06.
07.
08.
09.
10.
11.
12.
13.
14.
15.
16.
Controll-A-Door
®
S
Instruction Manual6