Introduction  EtherProx Entry 
The following table contains the secure and traffic control installation configurations for 
entry hardware, exit hardware, DIU, door control wiring, and sounder wiring. 
INSTALLATION  ENTRY 
HARDWARE 
EXIT 
HARDWARE 
DIU  DOOR CONTROL 
WIRING 
SOUNDER 
WIRING 
Traffic control 
(see Figure 2) 
Entry reader  REX switch  No  Entry reader  Not 
applicable 
Traffic control 
(see Figure 3) 
Entry reader  Exit reader  No  Entry reader  Not 
applicable 
Secure (see 
Figure 4) 
Exit reader  Entry reader  No  Entry reader  Exit reader 
Secure (see 
Figure 5) 
Entry reader  REX switch  Yes  DIU  DIU 
Secure (see 
Figure 6) 
Entry reader  Exit reader  Yes  DIU  DIU 
The following diagrams contain the secure and traffic control installation configurations 
for entry hardware, exit hardware, DIU, and door control wiring. The diagrams 
illustrate how to configure the hardware. For details on connector pins and power 
wiring, see section 4, “InfoProx Hardware Installation.” For details on the DIU, see the 
DIU Installation and Operation Manual. 