EtherProx Entry  EtherProx Entry Installation 
3.  EtherProx Entry Installation 
EtherProx Entry mounts directly onto a standard UK or European (French) electrical 
containment box. North American installations require an adapter plate so you can use 
standard conduit and fittings. A clear polycarbonate screen covers the LCD for protection. 
You pull the cables through the conduit, which terminate in the containment box. The 
following cables are required: 
CABLE  CONNECTOR 
Category 5 data network cable  4-pin socket (J5) 
4-pair (max) cable for inputs and output  10-pin socket (J2) 
2-pair (Belden 8723) cable to exit reader  4-pin socket (J3) 
The EtherProx Entry unit uses Phoenix Contact connectors for inputs and outputs. You 
secure the cables into the screw terminals. Belden 8723 or equivalent cable is 
recommended for the 2-pair cable. 
EtherProx Entry provides two stainless steel tamper-resistant mounting screws. These 
screws are concealed behind specially molded covers when the installation is complete. 
Note  The connectors on the EtherProx Entry reader are keyed to ensure 
correct orientation. 