Administering EtherProx Entry  EtherProx Entry 
Configure Door 
The following table lists the Configure Door settings with their descriptions. 
CONFIGURE DOOR SETTING  DESCRIPTION 
Unlock Time  Length of time that the lock is released 
Relock Delay Time  Number of seconds to delay the relock 
after a door is detected as open. You must 
enable Door Sensing for this setting to 
work. 
Standard Door Open Time  Length of time a door can be open before 
an alarm is generated. You must enable 
the Door Sensing for this setting to work. 
Extended Door Open Time  Length of time a special status card can 
hold a door open before an alarm is 
generated. You must enable the Door 
Sensing for this setting to work. 
Door Held Warning  Length of time a door held warning sound 
is generated on the reader before the 
alarm goes off. You must enable the Door 
Sensing for this setting to work. 
Alarm Sounder Duration  Length of time a door held open alarm or 
door forced open alarm warning is 
generated. You must enable the Door 
Sensing for this setting to work. 
Powered to Secure  Specifies whether power to the lock 
secures the door (default). 
Powered to Unlock  Specifies whether power to the lock 
unlocks the door. 
Door Sensing Enabled  Specifies whether a door state switch is 
connected. If you disable this setting, the 
Standard Door Open Time, Re-lock Delay 
Time, Extended Door Open Time, Door 
Held Warning, and Alarm Sounder 
Duration settings will be disabled. 
Lock Sensing Enabled  Specifies whether a lock status switch is 
connected. 
Request to Exit Enabled  Specifies whether an exit pushbutton 
switch is connected. 
Page 36 Software House 