S610S Manual - Hardware Installer Manual - Version 1.8 
50 
10.3   Information Menu 
Use this menu to easily read the IP address, MAC address, RTC and Web addresses the reader is 
using. 
Network 
RDR address - 
 entered by an installer using the Diagnostic Keypad. The third digit from the right is 
the actual address of the reader, B in the example below. 
The address of the reader in the example above is B 
Versions 
Software Type - Indicates the reader type, determined by the firmware, e.g. S610S 
Software version - Firmware version, currently, B1.00.041 
Software date - Release date of the firmware currently installed on the reader 
Hardware version - Version of reader hardware as at manufacturing 
HW serial No - Hardware serial number 
Database 
DB Format - 3 & 4 byte indicated only card numbers are held in the reader’s Off Line database, “8 
byte” indicates the Card Number, Timezone, status and PIN are all held in the readers Off Line 
database. 
DB free space - 223424 
Cards - Number of card details held in Off Line database 
Transactions - Number of transactions held in Off Line database 
Last Configuration time - “Not configured” means that the reader has not yet successfully received a 
configuration from the controller, other wise the time of the last configuration from the controller is 
displayed. 
Timezones - PZ - CZ - OZ 
SMART Keys - No KEYS Loaded 
System 
DIU - yes/no 
Exit Reader - active/inactive 
Door Mode - current mode of reader is reported 
Local Keypad - enabled/disabled 
Exit Keypad - enabled/disabled 
Relay State - reports current state of master and Exit reader relays, 0, 1, 2, 3. 
2
nd
 Relay Action - not supported 
Sounder Action - Sounder enabled/Disabled 
Diagnostic card - enabled/disabled. Installers can use special cards which allow direct access to the 
diagnostic mode. Normally disabled. 
Card Format - current card Format read by readhead is reported 
Tamper values - High and Low tamper values reported 
Prox Head - shows Prox Head ON or Off, and whether SmartHead enabled/disabled. 