User's Manual

Table Of Contents
S700 Installation Manual
41
Typical Wiegand read head wiring
For specific read head wiring, consult the third-party manufacturer.
Important: For regulatory compliance, the drain wire must be disconnected at the reader-end of
the cable.
Input configuration
Table 15: S700 and third-party read head input configuration illustrates the configuration and
operation of the inputs on the terminal when configured with a third-party Wiegand read head.
Product CEM Product Code
HID iClass SE R10 SmartCard Reader HDS/053/010
HID iClass SE R30 SmartCard Reader HDS/053/030
HID iClass SE R40 SmartCard Reader HDS/053/040
Table 13: Read head product code
I/O board connection Typical HID colour
GND Black
Sounder Yellow
Green LED Orange
Amber LED Not fitted
Red LED Brown
Data 1 White
Data 0 Green
Head 12V Red
Table 14: Typical Wiegand head wiring
Input number Input function Default input trigger state change
0 Door position short => open
1 Lock position short => open
2 Request to exit switch open => momentary short => open
3 Spare / Interlock short => open