Using Desfire EV1
There are two different types of Desfire EV1 card. CEM can provide a personalised Desfire
EV1 card, with pre-defined attributes or non-personalised Desfire EV1 cards can be used. If
using non-personalised cards, the user should refer to the User Defined Keys manual to
configure card keys.
1.1.2 Terminal dimensions
Figure 2 Illustration of emerald including dimensions
1.1.3 Part ratings
emerald has been tested and will work within the ranges specified in the table below.
Part Rating
emerald terminal -20º to 70ºC (-4º to 158ºF) flame retardant polycarbonate, rated to IP65
DC power (unit only)
12V nominal (10V – 14V) @500mA peak. (typically 300 - 400mA)
a
a. If the power supply is less than 12V @ 500 mA a separate PSU is required to power the lock
Power over Ethernet
(PoE+)
15W - power to the terminal only. Lock and/or exit reader power should
be supplied separately.
Inputs Four analog inputs - voltage supplied
Comms to exit reader RS485 serial comms
Comms to system host 10/100 Base-T TCP/IP CAT5/5e/6
Dry contact outputs 30vDC @ 5a
Table 3: Table of part ratings