Worldwide Testing Services(Taiwan) Co., Ltd Page 15 of 19
Polarization: Vertical
Frequency
(MHz)
Reading
(dBuV)
Detector
Factor
(dB)
Result
(dBuV/m)
Limit
(
dBuV/m
)
Margin
(dB)
Table
Degree
(Deg.)
Ant.
High
(cm)
114.9498 2.27 peak 12.81
15.08 43.50 -28.42
40 100
Frequency
(MHz)
Reading
(dBuV)
Peak
Factor
(dB)
Corr. Duty
Result @3m
(dBuV/m)
Peak Ave.
Limit @3m
(dBuV/m)
Peak Ave.
Margin
(dB)
Table
Degree
(Deg.)
Ant. High
(cm)
600.2003 24.67 23.20 -13.96
47.87
33.91
74.67
54.67
-20.76 145 100
900.4008 21.55 27.15 -13.96
48.70
34.74
74.67
54.67
-19.93 190 100
1200.4010 52.07 -9.52 -13.96
42.55
28.59
74.00
54.00
-25.41 210 100
1500.0000 44.49 -9.05 -13.96
35.44
21.48
74.00
54.00
-32.52 145 100
1800.0000 43.98 -7.01 -13.96
36.97
23.01
74.67
54.94
-31.93 80 100
2100.0000 43.61 -5.77 -13.96
37.84
23.88
74.67
54.94
-31.06 30 100
Note 1. Correction Factor = Antenna factor + Cable loss - Preamplifier
2. The formula of measured value as: Test Result = Reading + Correction Factor
3. Detector function in the form : PK = Peak, QP = Quasi Peak, AV = Average
4. All not in the table noted test results are more than 20 dB below the relevant limits.
5. Measurement uncertainty for 3m measurement: 30-1000 MHz = ± 3.68 dB, 1-18 GHz = ± 5.37
dB, 18-40 GHz= ± 3.43 dB ; Reported uncertainties represent expanded uncertainties expressed
at approximately the 95% confidence level using a coverage factor of k = 2.
6. See attached diagrams in appendix.
All other not noted test plots do not contain significant test results in relation to the limits
Test results: The unit meet the FCC requirements.
Test equipment used: ETSTW-RE 004, ETSTW-RE 030, ETSTW-RE 111