User's Manual

Registration number: W6M21409-14450-C-1
FCC ID: SU7300MCD21V2-CG
Worldwide Testing Services(Taiwan) Co., Ltd Page 18 of 19
3.8 Duty Cycle
The correction factor, based on the channel dwell time in a 100ms period, may be mathematically
applied to a measurement made with an average detector, to further reduce the measured value.
Average Reading = Peak Reading (dBuV/m) + Duty Cycle Correction
Duty Cycle Correction = 20 log (Cycle)
In order to determine the Duty Cycle, the EUT is measured as:
Testing Mode T period
(ms)
T on
(ms)
Duty Cycle Duty Cycle Correction
20*log(Duty Cycle)
Transmitting Mode 100 20.04008 0.200400802 -13.96
Explanation: See attached diagrams in appendix.
Test equipment used: ETSTW-RE 055, ETSTW-RE 004