Model BC-2010 HID&EM Keypad/Reader/Controller User Manual
1. Packing List Name Digital Keypad-BC-2010 Quantity 1 Remarks User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing Self tapping screws 4 3.5*27mm, used for fixing Please ensure that all the above contents are correct. If any are missing please notify the supplier of the BC-2010. 2.
. Description The BC-2010 is single door multifunction standalone access controller or a Wiegand output keypad or card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It is housed in a strong, sturdy and vandal proof Zinc Alloy electroplated case which is available in either a bright silver or matt silver finish. The BC-2010 supports up to 1500 users in either a Card, 4 digit PIN, or a Card + PIN option.
5.
7.
NO and COM: Fail-secure lock, when power on, the lock is opened. NC and COM: Fail-safe lock, when power off, the lock is opened. 8. To Reset to Factory Default To reset to factory default, power off the device, remove the keypad from the back cover, press the RESET key(K2) on the PCB, hold it and power on, keeping pressing it until hear three beeps, means reset to factory default successfully. Note: Reset to factory default, the user’s information is still retained. 9.
To change the master code 0 New code # New code # The master code can be 6 to 8 digits long Setting the working mode: Set valid card only users 3 0 # Entry is by card only Set valid card and PIN users 3 1 # Entry is by card and PIN together Set valid card or PIN users 3 2 # Entry is by either card or PIN (default) To add a user in either card or PIN mode, i.e. in the 3 1 To add a Pin user 2 # User ID number mode.
To delete a card user by card. Note users 2 Read Card # can be deleted continuously without exiting programming mode To delete a card user by user ID.
11.2 Door Settings Relay Output Delay Time To set door relay strike time 4 0~99 #* 0-99 is to set the door relay time 0-99 seconds Door Open Detection Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically. Door Forced Open warning.
12. Interconnecting Two Devices 12.1 BC-2010 operating as a Wiegand Output Reader In this mode the BC-2010 supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit input. See figure 1. Figure 1 12.2 BC-2010 operating as a Controller In this mode the BC-2010 supports a Wiegand 26 bit input so an external Wiegand device with a 26 bit output can be connected to the Wiegand input terminals on the BC-2010.
12.3 Two BC-2010 units interconnected for a single door In this mode two BC-2010 units are used for a single door, one for entry and the other for exit. Either device acts as the controller and reader at the same time. Users can be enrolled on either of the devices. In this mode the user capacity for one door can be up to 3000. The setting of the two BC-2010 units must be the same including the master code. See figure 3.
FCC WARNING This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE 1: Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.