SEBURY SAM-1000 Digital Keypad
Introduction The SAM-1000 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming is done through the keypad. Codes and operating parameters are stored within the microprocessor and can not be lost due to power failure. The SAM-1000 can store 1000 prox cards and user 4 digit codes. Each 4 digit code has 10,000 possible combinations. The unit has one relay with 5 Amp contacts.
Specifications 1. Programmable Functions Relay latching or momentary Relay activate independently or together Change Codes 1 master, 1000 users & prox cards Door open detection 2. Programmable Timers Door relay time 00-99 seconds Door open detection 00-99 seconds Alarm time 00-99 minutes 3. Wiring Connections Electric lock External bell External Push Switch Magnetic Contacts Alarm 4. Keypad: 12 keys 5.
Figure 1 Figure 2 Mounting 1. Attach the rear plate to a single or double gang electrical box or secure to the wall firmly with at least three flat head screws. 2. When wiring has been completed, attach the front cover to the rear plate.
Figure 4 The front cover can be permanently secured by using the short screw supplied SAM-1000 Printed Circuit Board Wiring 1. Unplug the cable harness and connect the necessary cables, (See Figure 5). 2. Tape any wires that are unused. 3. Plug the cable harness , (See Figure 5) 4. Attach the front cover, (See Figure 3).
Figure 5 Power Up 1. After all wiring is complete and the unit face plate is attached to the back plate, apply 12Vdc power to the unit. Accept LED(the yellow LED) flashing. Engineer Programming Mode To enter programming mode Press: * 9999 # within 5 seconds, Ready(the green LED) and Accept LED illuminated, Open LED flashing. Note Press: # to save changes and exit engineer programming, when all programming has been completed otherwise changes will not be saved.
Upon acceptance Open LED illuminates and stops flashing. Press * after changing the master code, otherwise unit will disregard the new code and revert back to the factory default code. Note: the master code must be 4-8 digit number.
Press: Press: 6 00 6 01 # # to disable this function (factory setting) to enable this function. In order for this feature to work, door contacts must be connected. There are 2 programming functions that work together in this mode. a.) If door not closed after opening, keypad buzzer sounds. b.) If door forced open, keypad buzzer sounds and sends alarm signal. Setting Security Arrangement There are two levels of keypad security available for the SAM-1000.
Alarm output load: Tamper Protection: Codes : Keypad: Card Types: Induction Distance: Wiring Connections: 150mA pull current Negative loop, normally closed 1 Master, 1000 cards and 1000 codes .
FCC WARNING This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The antenna provided is a unique antenna. By installation of unauthorized antenna to this equipment. Such unauthorized installation could void the user's authority to opearte the equipment.