User's Manual
5
Figure 4
The front cover can be permanently secured by using the short screw supplied
SAM-1000 Printed Circuit Board
Wiring
1. Unplug the cable harness and connect the necessary cables, (See Figure 5).
2. Tape any wires that are unused.
3. Plug the cable harness , (See Figure 5)
4. Attach the front cover, (See Figure 3).
Terminal Wire Connector 1 Function
10 Bell1 White Bell Push Button
9 Bell2 White Bell Push Button
8 12V Red (+) 12Vdc Positive Regulated Power Input
7 GND Black (-) Negative Regulated Power Input
6 COM Orange Door Strike Relay Com
5 NO Blue Door Strike Relay N/O
4 NC Green Door Strike Relay N/C
3 D_IN Brown To Door Contact Then To Door In
2 OPEN Yellow To Door Remote Control Button Then Negative
1 ALARM Grey Alarm
Warning! Do not plug adaptor our transformer into mains until all