User's Manual
7
Upon acceptance Open LED illuminates and stops flashing. Press * after
changing the master code, otherwise unit will disregard the new code and revert back
to the factory default code.
Note: the master code must be 4-8 digit number.
Adding User Codes & Cards
To Add User cards & codes
Press: 1 read card user identification #
Note: the user identification must be 3 digit number, if adding more than 1 card, read
the next card after inputting the 3 digit code for the previous card, when you have
finished adding all cards press the # key. 1
st
card must be 000 up to 999.
Then the SAM-1000 control station added a user card it was auto added a user code
with 1234.
Delete User Card or Cards
There are 3 options to delete a user card or cards, in engineering mode.
a.) Press: 2 0 0 0 0 # to delete all user cards
b.) Press: 2 read card # to delete individual user card
c.) Press: 2 user identification number # to delete individual user card
User Operation Mode
There are 3 different options for user operation mode, card only, card and password,
valid code. The optioned used is common to all users.
Press: 3 0 0 # valid card only
Press: 3 0 1 # valid card and password
Press: 3 0 2 # valid card or password
Setting Door Relay Strike Time
The door relay output can be operated as either normally opened or normally closed,
a maximum current of 10 ampere can pass through the relay if used as normally
opened or 5 ampere if normally closed. The door relay time can be set from 0
seconds to a maximum of 99 seconds. The factory default setting is 6 seconds and
can be changed through the keypad.
Press: 4 new time from 00-99 seconds #
Setting Alarm Signal Output Time
Press: 5 new time from 00-99 minutes #
Setting Door Open Detection