User's Manual

8
Press: 6 0 0 # to disable this function (factory setting)
Press: 6 0 1 # to enable this function.
In order for this feature to work, door contacts must be connected. There are 2
programming functions that work together in this mode.
a.) If door not closed after opening, keypad buzzer sounds.
b.) If door forced open, keypad buzzer sounds and sends alarm signal.
Setting Security Arrangement
There are two levels of keypad security available for the SAM-1000.
Press: 7 0 1 # to read 10 invalid cards or valid cards, then enter 4 wrong
passwords in succession, the keypad is locked for 10 minutes.
Press: 7 0 2 # to read 10 invalid cards or valid cards, then enter 4 wrong
passwords in succession, the keypad activates and alarm signal.
To disable this feature:
Press: 7 0 0 # factory default setting.
Resetting To Factory Default Setting
To revert all settings to the factory default values then the Non Volatile Memory
(Eeprom) must be reset.
Reset Non Volatile Memory by switching of the power and placing the jumper
connector onto the pins 1 & 2 as per figure 2. After switching power on remove
jumper, the SAM-1000 will give a beep and is now reset to factory default values.
Changing User Password Code
The factory default setting for each user password code 1234, this can be modified so
that each user has a unique individual 4 digit code.
Press: * read user card user passoword # new password # re-enter
new password #
Using Password Code to release the door
Press: user passoword #
Technical Specification
DC Supply Voltage: Low voltage input 12 ±10% Vdc unregulated
Current Consumption: 100mA @ quiescent maximum
Door Relay: 5Amp 12Vdc