SK1-H Waterproof Access Control/Reader User Manual
INTRODUCTION The SK1-H is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to perform in a wide range of indoor, outdoor, and harsh environments. The SK1 supports up to 1000 users in multiple access configurations (Card, Card or PIN, or Card + PIN). The built in card reader supports HID 125KHz frequency cards.
Adjustable Alarm Output Time Lock Output Load Alarm Output Load Wiegand Interface Environment Operating Temperature Operating Humidity Physical Surface Finish Dimensions Unit Weight Shipping Weight 0-3 minutes (1 minute default) 3 Amp Maximum 3 Amp Maximum Wiegand 26-37 bit input/output Meets IP66 -30℃ ~60℃, or -22°F ~ 140°F 10% ~ 90% Non-Condensing Zinc-Alloy Enclosure Powder Coat L: 120* W: 76 * H: 25 (mm) 600g 700g Carton Inventory SK1-H Access Controller Wall Anchors Self Tapping Screws Screw Driv
Attach the unit to the back cover.
Access Control Power Supply To Reset to Factory Default To reset to factory default, power off, press * , hold it and power on, release it until hear two beeps and the LED shines in orange, then read any two HID cards, the LED will turn in red, means reset to factory default setting successfully. Of the two HID cards read, the first one is Manager Add Card, the second one is Manager Delete Card. Remarks: Reset to factory default, the user’s information is still retained.
Standalone Operation 1.
Maximum 1,000 cards can be enrolled at a stretch within 1 minute.
For a card User Read card For a card and PIN user Read card then enter PIN # 1.2 Master Cards Using Using Master Card to add and delete card users 1. (Read Master Add Card) 2. (Read User Card) Add a User Card Repeat Step 2 for additional user cards 3. (Read Master Add Card) 1. (Read Master Delete Card) 2. (Read User Card) Delete a User Card Repeat Step 2 for additional user cards 3. (Read Master Delete Card) 1.
lockout default) or alarm (factory Keypad Lockout 7 1 # Alarm Output 7 2 # Light and Sound Setting To set keypad backlight 7 4 # To disable keypad backlight 7 5 # To enable the keypad backlight (factory default) To set LED 7 6 # To disable the red LED 7 7 # To enable the red LED (factory default) To set keypad tone 7 8 # To disable the keypad tone 7 9 # To enable the keypad tone (factory default) Alarm output time To set the alarm output time (0~3 minutes) 9 0~3 # Factory default is 1 minute
Wiegand Mode Wiegand Format Setting SK1-H supports Wiegand 26~37, both input and output. It can be used as a reader or controller. To Set Wiegand format: 9 26~37 # (Default setting: Wiegand 26) Pass through mode (SK1-H operating as a Wiegand Output Reader) In this mode the SK1-H supports a Wiegand 26~37 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26~37 bit input, then the SK1-H will be operated as a slave reader.
connected to the Wiegand input terminals on the SK1-H. Either an ID card reader (125 KHz) or an IC card reader (13.56MHz) can be connected to the SK1-H. Cards are required to be added at the external reader, except where an external HID reader is used, in this case cards can be added at either reader or controller.
SK1-H- Simplified Instruction Function Description Operation Enter the Programming Mode * (Master Code) # Change the Master Code 0 ( New Master Code ) # ( Repeat New Master Code)# (code: 6 digits) Add Card User 1 (Read Card) # Add PIN User 1 (User ID) # (PIN) # (666666 is the default factory master code) The ID number is any number between 1 ~ 1000.