3. EnterthedesiredForcedDoorOutputtime.For
example:
45#ttt#0#**
where, ttt=forced door time, to nearest 10’s
seconds, entered as 10-990; default=30 seconds.
4. Press * to exit Program mode.
4.4 Programming
Keypad Options
and Parameters
4.4.1 User Lockout
Option
The prox.pad plus unit supports two types of user
lockouts: “Lockout By Location” and “Lockout By
Group.” The two lockouts share the following features:
(1) entering Program mode always clears an active
lockout (2) and neither the “master,” the“ supervisor,”
nor an “emergency” user can be locked o ut. The user
lockout function, which is enabled by default, can be
disabled through Command 30 option #5. The lockout
type is selected through Command 30 option #8 and
defaults to “Lockout By Location.”
4.4.1.A Lockout By Location
In the Lockout By Location mode, the location of the
Lockout Code in the user table determines w hich users
are locked out. E ntering a Lockout Code (when no
lockouts are active) excludes all users programmed in
locations greater than the location of that Lockout
Code. For example, if user #20 is p rogrammed as a
Lockout Code and that user’s PIN is entered, then
users #21 and above are locked out.
Entering the same Lockout Code cancels the current
lockout. If a different Lockout Code (programmed in
a location less than the current lockout) is entered
during an active lockout, the lockout is “lowered” to
the location of that PIN. T his means that to cancel a
Chapter 4: Programming 4.4 Programming Keypad Options and Parameters
4-20 prox.pad plus Install/Program. Manual, PPP, D4b