THE 455 D CONTROL PANEL: SUPPLEMENTAL INSTALLATION INSTRUCTIONS November, 2003 455 D Control Pa nel Ins tallation Ins tructions CONTENTS General Description 2 Installing the 455 D Control Panel 2 Connect the Main Power Supply 2 Connect the Operator(s) to the Control Panel 3 Check the Motor’s Direction of Rotation 3 Connect Other Devices 4 Set Other Operating Controls 6 Programming 8 Learning of Operating Times 10 Learning of Normal Times 10 Learning Times with Gatecoder 10 Automated
November, 2003 455 D Control Pa nel Installat ion Instr uctions P a ge 2 THE 455 D CONTROL PANEL GENERAL DESCRIPTION The FAAC 455 D control panel is used to operate the following models. NOTE: An installation is U.L. compliant only when you install the FAAC operators according to the UL325 standards.
November, 2003 455 D Control Pa nel Installation Instructions P a ge 3 In order to wire motor 2 in a bi-parting system, connect the white wire to terminal 4 (on the J4 terminal strip), the black wire to 5, the red wire to 6. Wire each leg of the capacitor (supplied) to terminals 5 & 6. CONNECT THE OPERATOR(S) TO THE CONTROL PANEL WARNING! Turn the main power off before you make any electrical connections or before programming.
November, 2003 455 D Control Pa nel Installat ion Instr uctions P a ge N 22 23 24 25 L 1 2 3 4 5 6 COM OP CL COM OP CL 115 VAC +/- 10% or 230 VAC +6/ -10% 50-60 Hz C1 M1 8 9 10 11 12 13 14 15 16 17 18 19 CL OP LAMP - - - FSW MOTOR 2 BLUE BLUE MOTOR 1 7 + + 24V 20 21 - FSW W.LIGHT LOCK ELECTRIC LOCK C2 FOR WHEN THE FAAC GATECODERS ARE USED 24 vdc 3W M2 OPEN Figure 2.
November, 2003 455 D Control Pa nel Installation Instructions (a) P a ge 5 (b) To the U. L. Listed gate operator U.L. Listed cord grip U.L. Listed Control Panel Enclosure 455 MPS Control Panel Junction box High-voltage terminal strip Legend Figure 3. Wiring detail (a) inside the junction box and (b) from the junction box or operator to the highvoltage terminal strip on the 455 D control panel White J3 Red Black Yellow/ Green To the U.L.
November, 2003 455 D Control Pa nel Installat ion Instr uctions P a ge 6 opening and closing, respectively, are triggered. Use the LEDs and the next table to determine if the accessory devices you have installed are operating properly. Electric Locks: An electric lock can be wired to the 455 D in terminals 18 and 21 (12Vac pulsed provided). If a reversing stroke is needed to allow the electric lock to release, this must be done in advanced programming.
November, 2003 455 D Control Pa nel Installation Instructions P a ge 7 Magnetic Lock Free Exit Loop/ Phone/ Firebox (Hold Open Dev ices) + Lock 17 9 NO 14 14 C 18 12 vac Relay N.C. N.O. 21 COM Shadow Loop FAAC Rev ersing Photocells (f or opening) Additional Reversing Devices 1 TX 2 19 17 C 12 NC Coil Voltage = Motor Voltage Additional Reversing Devices 1 13 19 N.C. 2 14 N.O.
November, 2003 455 D Control Pa nel Installat ion Instr uctions P a ge 8 PROGRAMMING BASIC PROGRAMMING To program the automated system, the “Programming Mode” must be accessed. Programming is split into two parts: ADVANCED. F BASIC and Display BASIC PROGRAMMING To access BASIC PROGRAMMING, press the “F” key. • If you press it (and hold it down), the display shows the name of the first function.
November, 2003 455 D Control Pa nel Installation Instructions P a ge 9 ADVANCED PROGRAMMING + + F Display Function Default MAXIMUM TORQUE AT INITIAL THRUST: The motors operate at maximum torque (ignoring the torque setting) at start of movement. Useful for heavy leaves. 4 = Enable No = Disabled LAST STROKE AT CLOSING: The motors are activated at full speed for 1s to facilitate locking of the electric lock.
November, 2003 455 D Control Pa nel Installat ion Instr uctions P a ge 1 0 LEARNING OF OPERATING TIMES WARNING: During the learning procedure, the safety devices are disabled! Therefore, any traffic must be avoided in the path of the gate leaf(s). • • NOTE: Must start with gate(s) in the closed position. Opening/closing time is established by the learning procedure which varies slightly according to whether you are or are not using Gatecoders. LEARNING OF NORMAL TIMES Normal learning (i.e.
November, 2003 455 D Control Pa nel Installation Instructions COMPLETE LEARNING P a ge 1 1 • NOTES: • If only one gate operator (1) is used, you must go through the entire programming procedure, as if you were programming a gate operator (2). When the gate operator (1) has finished opening, supply 5 open commands until the gate operator begins to close, and then resume normal operations.
November, 2003 455 D Control Pa nel Installat ion Instr uctions P a ge 1 2 A (Automatic) Logic (455 D) Gate Status Open A Opens both leaves Closed and closes them after pause time Open B Stop Opening Reversing Device(s) Closing Reversing Device(s) Warning Light No effect No effect No effect Off Stops when reversing device no longer trig- No effect On Opens single leaf connected to Motor 1 and closes it after pause time Stops; gate closes Opening No effect No effect gered Interrupts th
November, 2003 455 D Control Pa nel Installation Instructions P a ge 1 3 E (Semi-automatic) Logic (455 D) Gate Status Open A Open B Closed Opens both leaves Stop Opening Reversing Device(s) Closing Reversing Device(s) Warning Light No effect No effect No effect Off No effect On Opens single leaf connected to Motor 1 Stops; gate closes Opening Stops Stops Stops when reversing device no longer triggered No effect Opened Closes both leaves Closes leaf Stops No effect (opening is inh
November, 2003 455 D Control Pa nel Installat ion Instr uctions P a ge 1 4 SAFETY • • • • IN GATE DESIGN • The operating controls for an automatic gate must be secured to prevent the unauthorized use of those controls. • The controls for an automatic gate should be located far enough from the gate so that a user cannot accidentally touch the gate when operating the controls. • Your gate must be properly installed and must work freely in both directions before the automatic operator is installed.
November, 2003 455 D Control Pa nel Installation Instructions This page is left blank intentionally.
November, 2003 455 D Control Pa nel Installation Instructions P a ge 1 6 LIMITED WARRANTY To the original purchaser only: FAAC International, Inc., warrants, for twenty-four (24) months from the date of invoice, the gate operator systems and other related systems and equipment manufactured by FAAC S.p.A. and distributed by FAAC International, Inc.