Wireless Transmitter Programming (Continued)
Delete single Enrolled Transmitter
Delete a single enrolled transmitter from the system.
1. If not alreay in Programming Mode, connect by telephone or use the local
keypad. Enter the master password and access programming.
2. Press
3. Enter the transmitter facility code.
4. Press
5. Enter the transmitter ID number of the transmitter.
6. Press
7. Exit Programming Mode if all programming is complete.
System Options
For most installations the factory settings for the system will be appropriate.
To customize the system, enter programming mode via telephone or local
keypad.
Display Language
Select the language of the front panel display.
1. Press
2. Choose a language: Enter 1 for English, Enter 2 for Spanish, Enter 3 for French
3. Press
Keypad Lockout Count
The system counts the number of invalid entry codes entered at the local or
remote keypad. The factory setting for the lockout count is fi ve. The lockout value
can be from two to seven.
1. Press
2. Enter the number for the lockout count (2-7).
3. Press
4. Exit Programming Mode if all programming is complete.
Relay Activation Time
The factory setting will cause the relays to activate for two seconds. The activation
time can be set from 1-60 seconds to accommodate different types of access
control devices.
1. Press
2. Choose which relay to set:
Enter 1 for Relay Channel “A”
Enter 2 for Relay Channel “B”
3. Press
4. Enter the number of seconds for activation (1-60).
5. Press
6. Exit Programming Mode if all programming is complete.
Relay Channel “B” Function
Relay Channel “B” is normally used to control a second access device. Alternately,
Relay Channel “B” can be used for alarm contact shunting, obstacle sensing
output, or triggering audible alarms.
1. Press
2. Enter a number for the Relay Channel “B” function:
Enter 0 for normal access control.
Enter 1 for Alarm Contact Shunt (Relay “B” will activate when Relay “A”
activates.
Enter 2 for activation when an MGT obstacle transmitter triggers. Wire
Relay “B” contacts to access device obstacle input (see PPN #55).
Enter 3 for triggering audible alarms on specifi c conditions.
3. Press
4. If any number but 3 was entered above, skip to Step #8.
5. Enter the audible alarm option:
Enter 1 for forced entry activation (activates if the sensing input is set for
Door Sense and detects an open access portal condition without access
being granted by the system).
Enter 2 for door/gate ajar activation (activates if the sensing input is set for
Door Sense and still detects an open access portal condition one minute
after access was granted by the system).
Enter 3 for activation during local or remote keypad lockout.
6. Press
7. Exit Programming Mode if all programming is complete.
PPN 51
51#COUNT#
COUNT = NUMBER (2-7) OF INCORRECT
ENTRIES REQUIRED FOR LOCKOUT
KEYPAD LOCKOUT COUNT
FACTORY SETTING: 5 TRIES
PPN 52
52#RELAY#SECONDS#
RELAY = 1 FOR RELAY CHANNEL "A"
RELAY = 2 FOR RELAY CHANNEL "B"
SECONDS = ACTIVATION TIME (1-60 SECONDS)
RELAY ACTIVATION TIME
FACTORY SETTING: 2 SECONDS
PPN 53
53#FUNCTION#ALARM#
FUNCTION = 0 FOR NORMAL ACCESS CONTROL
FUNCTION = 1 FOR ALARM SHUNT
FUNCTION = 2 FOR MGT OBSTACLE TRANSMITTER
FUNCTION = 3 ALARM ON CONDITION
ALARM = 1 FOR ACTIVATE ON FORCED ENTRY
ALARM = 2 FOR ACTIVATE ON DOOR OR GATE AJAR
ALARM = 3 FOR ACTIVATE ON KEYPAD LOCKOUT
RELAY CHANNEL "B" FUNCTION
FACTORY SETTING: NORMAL ACCESS CONTROL
PPN 47
47#FC#ID#
FC = FACILITY CODE (0 IF UNUSED)
ID = TRANSMITTER ID NUMBER
DELETE SINGLE ENROLLED TRANSMITTER