User guide

INSTR,INSTL,DTG
Linear P/N: 211906 B
Material: 20 Lb. Mead Bond
Size 8.500" x 11.000"
Ink: Black
Side 1 of 2
Scale: 1-1
DTG
GATE SAFETY EDGE
TRANSMITTER
Installation
Instructions
(800) 421-1587 www.linearcorp.com
DESCRIPTION
The DTG is part of Linear’s Delta-3 product line and is compatible with all Delta-3
products. In a typical installation, the DTG is mounted on a motorized gate, door
or barrier arm and wired to a standard exterior safety edge sensor which
presents a closed circuit across the connecting wires when an object is hit during
the closing of a gate. To insure full compatibility with all gate edge safety
features, Linear recommends Miller gate edge sensors. If the edge sensor is
pressed for a minimum of 1/8 second, the DTG transmits a message to the
receiver to reverse the movement of the gate.
The DTG circuit board has been coated to prevent moisture damage and is
mounted inside a weather resistant fiberglass box. The mounting box attaches
to the gate through sealed interior mounting screws.
DTG
TRANSMITTER
SAFETY EDGE
SENSOR
GATE
OPERATOR
TYPICAL
INSTALLATION
STEP 1
Remove Cover.
Loosen the four screws on transmitter top and
remove cover.
STEP 2
Locate Parts.
Refer to diagram below for transmitter parts location
and details.
STEP 3
Mount Safety Edge.
Mount safety edge according to manufacturer’s
instructions included with the product.
STEP 4
Mount DTG.
Choose a location as high as possible on gate in a
secure position. Use the template attached to mark the location for the
transmitter. You may have to attach a metal or wood plate to mount transmitter.
Use a 3/32" bit and drill holes. Attach DTG to gate using the four #6 self-tapping
drill point screws.
LOOSEN
SCREWS
REMOVE
COVER
SAFETY EDGE
INPUT TERMINALS
TEST
SWITCH
CODE SWITCH
KEYS
9 VOLT
ALKALINE OR
LITHIUM BATTERY
ANTENNA
TEST
INDICATOR
INSTALL
SAFETY EDGE
ATTACH DTG
TO PLATE
3.88"
1.77"
WELD PLATE
TO GATE