Operation Manual

6
®
7SEELEY INTERNATIONAL OWNER’S MANUAL
NGP series Portable Evaporative Cooler
MAINTENANCE cont.
12
ILL1268-A
6. If the pump drive belt needs replacing
simply remove it from the pulleys. Ensure
that the belt is replaced in the same
orientation as shown in the diagram (Fig
13) so that the pump rotates in the right
direction.
ILL1269-A
13
7. Replace the rear panel by placing the
bottom of the rear panel in the tank and
pivoting it forward until the clips engage
(Fig 09, Pg 5).
3.6 Fan/pump not running
fast enough on low speed.
3.7 Pump drive belt faulty
or broken.
3.6.1 Check that supply voltage is up to correct level.
3.6.2 Fan and pump will pick up speed slightly as the motor
reaches normal operating temperature. Allow the cooler to run for
30-60 minutes and check again. If there is no improvement have
the cooler checked by a service agent.
3.7.1 Replace drive belt as shown on page 6.
4.1 Reservoir or cooling
pad dirty.
4.2 Water quality is poor.
4.1.1 Drain reservoir and fill the cooler with clean water. If it still
smells clean the reservoir and replace the cooling pad or proceed
to 4.2.1.
4.2.1 Add a little vanilla essence or perfume to the water.
4. Cooler makes
bad smell.
5.1 Dirt has accumulated
inside pump.
5.1.1 Proceed as in 3.5.1
5.1.2 Replace drive belt as shown on page 6.
5. Cooler makes
scraping or rattling
noise on new
season start up.
6.1 Too much water in
reservoir.
6.1.1 Drain some water out (see page 5).
6. Water overflows
from reservoir.
7.1 Electrical fault.
7.1.1 Electrical parts must only be repaired and replaced by
Authorised Service Agents.
7. Cooler will not
operate at all.
8.1.1 If the power supply cord of this appliance is damaged it
must be replaced. Electrical parts must only be repaired and
replaced by Authorised Service Agents.
8. Damaged
power supply
cord.
3. No cooling.
3.1 Cooling control is off.
3.2 Reservoir is empty or
nearly empty.
3.3 Weather is too humid.
3.4 Aspen cooling pad and
/ or pump inlet screen
blocked or dirty.
3.5 Pump is not working
properly.
3.1.1 Turn cool knob to 'COOL'.
3.2.1 Fill with water again until water level indicator is at the
'FULL' position. Water capacity is 13 litres
3.3.1 Turn cool knob to '0' and use cooler as a fan only.
3.4.1 Clean parts - see maintenance page 5.
3.5.1 The pump is NOT a separate electric pump. It is connected
to the fan motor and is driven mechanically. Turn the cooler off
and completely drain the reservoir. Refill with water. Switch fan
knob to high speed (3), turn the cool knob to 'COOL',run the
cooler for 10-15 minutes non-stop. This will help dissolve and
flush out the dirt. The cooling pad should now be wet. If the pad is
not visibly wet and there is no cooling, have the cooler checked by
a service agent.
1. Cooler will not
operate at first.
2. Cooler stops
operating after
running for some
time.
1.1 Power outlet or supply
faulty.
1.2 Wrong voltage.
2.1 Motor overheated
(safety cutout).
1.1.1 Switch on power outlet.
1.1.2 Check power supply.
1.1.3 Check power outlet.
1.2.1 Check that power supply is the same as specified on the
rating label.
2.1.1 Wait 30-45 minutes for motor to cool down and it will restart
automatically. If condition persists take the cooler to a service
agent.
TROUBLESHOOTING
CONDITION POSSIBLE CAUSE REMEDY