Operation Manual

6
®
Millenia series Portable Evaporative Cooler
Air direction control Megacool
Model Megacool has motor driven vanes
that are switched on and off by the fan
control switch on the control panel (Fig
18). Set the control to the sweep / fan
speed setting to operate the sweep vanes
(shown). Set to fanspeed settings for
fixed direction.
There are no manual adjustment levers.
Cleaning the cooler
Important! Always switch off and
remove the electrical plug before
cleaning and servicing the
cooler.
To clean, wipe the cooler with a damp
cloth and a little household detergent.
The rear panel can be removed to gain
access to inside the cooler by removing
the screws at the top of each side.
Pivot the panel backwards and lift off
(Fig 20).
ILL880-B
20
Safety instruction
As this cooler contains water, ensure it is
moved carefully and is not tilted, as water
may spill (Fig 19).
ILL878-B
19
18
ILL1436-A
MAINTENANCE
DIRECTIONS FOR USE cont.
MAINTENANCE cont.
End of Season
At least once a year at the end of summer it
is advisable to do some simple maintenance
on your cooler to maintain its high efficiency.
This involves cleaning the water system and
the Aspen cooling pad.
To drain water
Drain the water from the cooler by moving the
cooler to a drain and removing the drain plug
located on the bottom of the tank. When the
cooler is empty replace the plug in the tank
(Fig 21).
ILL879-A
21
A
B
A
ILL882-B
22
Pump belt replacement
If a pump drive belt needs replacing, access
can be gained by using a tool (screwdriver) to
remove the small access door (Fig 22 - A).
Each cooler is supplied with a spare drain
plug, located in the position shown (Fig 22 -
B).
Spare drain plug
Water strainer and aspen cooling pad
Clean the water strainer by removing any
foreign matter. Wash the Aspen cooling pad
with water while it is still in the rear panel.
Replace the pad if it is worn or deteriorated.
7SEELEY INTERNATIONAL OWNERS MANUAL