5.3 Default Setting
CS208 is shipped out with default setting stored in the file factory.def. User can refer to
factory.def in the software package to define the default setting of CS208 reader and
reconfigure the reader.
User is required to define the default setting file as default.ini and download the file to
run CS208 the first time.
User can download the defined default.ini file from PC to CS208 via USB or Ethernet
download:
USB download:
1. Power on CS208 and wait 2 minutes.
2. Connect CS208 USB client cable to PC and make sure PC installed active sync(for
Window XP) or mobile center (for Window 7/8).
3. Open file exporter in PC and copy deault.ini into "CS208/Storage Card/CS208device"
folder.
4. Power off CS208.
5. CS208 will use new configuration when user restart CS208.
Network download:
1. Start demo program "CS208CommissioningAndFwUpgrade.exe" in "CS208-PC
Demo\CS208FWUpgrade\bin\Release" folder.
2. Power on CS208 and wait 2 minutes.
3. Screen show "connected from xxxxxx" (xxxxx is CS208 Device ID)
4. Select "default.ini only"
5. Press "upgrade" button
6. Wait until success message box is displayed.
7. Power off CS208
8. CS208 will use new configuration when user restart CS208.