User Manual

Copyright 2012 Page 39
Additional details describing the 5I EDSU operation are provided in Section 9.
5.4.1 OS Command: 5I Lenses Only
Retrieve Current 5I Channel Settings
Issue
OS[C/R]
Tag = O
Response
OrRdUC0.0cccWnninlSssssssssBx.xx[L/F][C/R]
Response( Unknown )
?[L/F][C/R]
Tag
Value
Definition
O
Tag
r
R
Focus Scale Ring Type currently fitted on lens: I = Imperial M = Metric
d
U
Display Units currently selected: I = Imperial M = Metric
C
0.0ccc
Film Size/ Circle of Confusion (CoC) Value (mm)
W
nn
Number Associated with Film Size (CoC) Value see Wnn Command
i
nI
Illumination Level [n=1 for 1 LED, n=2 for 2 LEDs, I = 0(min) 9(max)
S
sssssssss
Lens Serial Number
B
x.xx
Firmware Version Number
Example:
Issue: OS[c/r]
Response: OrIdIC0.0250W00Si105200-090 B4.90 [l/f][c/r]
Note: The Unknown response string will be issued by all non-5I lenses.
5.4.2 OT Command: 5I Lenses Only
Retrieve Baud Rate, Data Type, Display Units for Opposite Channel
Issue
OT[C/R]
Tag =Ot
Response
OtBbFfUu [L/F][C/R]
Response( Unknown )
?[L/F][C/R]
Tag
Value
Definition
Ot
Tag
B
b
Baud Rate of Opposite Channel: b=0 -7 [see Kbn Command]
F
f
f = A (ASCII), f = B (Binary)
U
u
Display Units currently selected: u=I (Imperial), u=M (Metric)
Example: