7. Baud Rates and Response Times
7.1 Implementation PANCHROI, RED & S4I Zooms; S4I Primes; 5I
Primes
Message transmission time is affected by the length of the data stream and baud rate.
Earlier S4I Prime and Zoom lenses with 10-bit ADC have slower clock speeds than the later
S4I Primes lenses with 12-bit ADC.
7.2 Table 6: Compare Calculation Time to Lens Type
Lens Type
ADC Type
Calculation Time
5I Prime
ALL
3.2 msec
PanchroI Prime
ALL
12 msec
S4I Prime
12-bit
10 msec
S4I Prime
10-bit
20 msec
S4I Zoom
12-bit
12 msec
S4I Zoom
10-bit
12 msec
RED
ALL
12 msec
7.3 Table7: Compare Repeat Rate (frames/second) to Lens Type
Lens Type
Command
Repeat Rate (Frames/sec)
Baud Rate
9600
Baud Rate
115200
Baud Rate
230400
5I Prime
D
11.8
97.1
144.9
Kd
21.6
140
185
miniS4I (PanchroI) Prime
D
11
53
N/A
Kd
17
66
N/A
S4I Prime (12-bit)
D
11
60
N/A
Kd
19
73
N/A
S4I Prime (10-bit)
D
9
37
N/A
Kd
16
42
N/A
S4I Zoom
D
11
53
N/A
Kd
17
63
N/A
RED
D
11
53
N/A
Kd
17
63
N/A