Operator`s manual

6
Cookshack SM160, SM260 & SM360 Operator’s Manual, V. 15.3
Electrical Specifications
SM160
Single burner system using 120VAC power.
Protect with a breaker or fuse rated at 15 amps.
SM260
Dual burner system using 208/220VAC power.
Protect with a receptacle with a NEMA L14-20R pin configuration
receptacle with a 208/220 VAC single-phase power supply protected by
a 20 amp fuse or circuit breaker.
SM360
Four-burner system using 208/220VAC power.
Protect with a Hubbell CS369 Receptacle with a 208/220VAC single-
phase power supply protected by a 50 amp fuse or circuit breaker.
Location
Ventilation is required for the proper operation of this unit.
Keep the oven free from combustible materials. A good rule of thumb is to allow
an 18 clearance space around unit.
Minimum spacing from combustible material is 6”; these clearances must be
maintained unless materials used are non-combustible. Following is the
recommended service spacing:
Front - Must have enough room to open door for loading and unloading of
product.
o SM160- 21”
o SM260- 27”
o SM360- 48”
Side - Must have at least 1 clearance around all sides.