DO NOT CONNECT THIS UNIT TO A FLUE SERVING ANOTHER
APPLIANCE.
Attachment and securement of the exhaust venting system to the product and to
each adjoining section of connector pipe are required to be fastened with at least
three screws.
The unit requires a separate 120 volt, 20 amp circuit. The unit must be grounded
in accordance to your local codes or with the National Electric Code ANSI/NFPA
70-1990.
Location
Stationary installation should be on a level surface.
The unit requires adequate air. Ventilation is required for the proper operation of
burner and cooking motors.
Keep the oven free from combustible materials. A good rule of thumb is to allow
an 18 inch clearance space around oven.
Minimum spacing from combustible material is 6”; these clearances must be
maintained unless materials used are non-combustible. Following is the
recommended service spacing:
Top 18”
Left Side 24” to load pellets
Right Side- minimum of 24”
Back- 4”
Front Must have enough room to open door for loading and unloading of
product (approximately 31”)
Floor–Keep combustible material 6” beyond each side of the firebox