Owner`s manual
In the event of a Possible Malfunction, your CookTek MagnaWave Cooktop
will display an Error Code on the LED Display. Please consult the following
table when encountering an Error Code.
Error Error Description Potential Cause Action Required
Code
1 RTD (temperature RTD sensor has shorted Reconnect or replace RTD.
sensor) is malfunctioning Service may be required.
2 RTD (temperature Glass surface is too hot or RTD Remove any pans from cooktop
sensor) temperature is sensor has broken surface and let unit cool. Then
too high turn unit off, then on. If problem
was temperature related, the unit
will return to normal operation,
otherwise service is required.
3 Current is too high Possible mechanical damage to Try different cookware. Service
coil or foreign object on cooktop. may be required
4 Electronics are Fan broken, bad ventilation, Check airflow. Clear air vents.
overheating ambient temperature too hot Listen for fan operation.
6 Input Line (From Power Something else is one the same To reset, unplug unit, wait
Outlet) Voltage Too High circuit. Line voltage fluctuations 5 seconds, and plug in again.
at end or beginning of work day. If problem persists, have an
(Voltage > 132Vac for 120V electrician monitor the line
model or > 264Vac for 240V voltage.
model)
7 Hardware failure Inverter I/O problem To reset, unplug unit, wait
5 seconds, and plug in again.
Service may be required.
8 Zero cross error Bad AC source, board Turn unit off, then on. Plug unit
component failure into outlet on different circuit
breaker. If problem persists,
service is required on device.
16 System error CPU I/O problem To reset, unplug unit, wait
5 seconds, and plug in again.
Two Hob (Two Position) Cooktops
Operation of the two hob (two position) Cooktop is exactly the same as the single
position Cooktop. Each position will have its own, independently controlled, On-
Off Control Knob and its own, separately controlled, SmarTemp button. It is not
necessary to turn on both positions for the Cooktop to function.
NOTE: For Proper operation a dedicated circuit should be used for each unit
installed. Each unit should be protected with a 30A minimum circuit breaker.
8