Instructions / Assembly

INSTALLATION INSTRUCTIONS
FOR
WHOLE HOUSE FANS
Models: CX242DDWT, CX302DDWT, CX24BD2SPD, CX30BD2SPD, CX36BD2SPD
Read all warnings and instructions before beginning to install this fan.
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN INJURY OR DEATH
1. Do not attempt to use this fan with any speed control device.
2. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
3. Before servicing or cleaning this unit, switch power off at the service panel and lock out to prevent power from being
switched on accidentally. When service disconnecting means cannot be locked, securely fasten a prominent warning tag to
the service panel.
4. Installation work and electrical wiring must be performed by a qualified person in accordance with all applicable codes and
standards, including fire-rated construction.
5. When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow
the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire and
Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air-conditioning Engineers
(ASHRAE), and the local code authorities.
CAUTION
DOUBLE CHECK FAN BLADES ARE SECURE TO HUB PRIOR TO INSTALLATION.
BLADES CAN BE DAMAGED DURING SHIPMENT AND CAN BECOME A HAZARD
UPON ACTIVATION OF MOTOR!
1. This unit has an unguarded propeller. Do not use in locations readily accessible to people or animals.
2. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
3. Carbon monoxide is an odorless, colorless gas that can kill. It may be drawn into the house by operating
this fan if your fuel-burning equipment is not properly maintained, or if you lack adequate attic space.