Installation Guide

Ventamatic, Ltd. | 100 Washington Ave, Mineral Wells, TX 76068 Phone: (800) 433-1626 www.bvc.com
7
Step 9: Hub Pairing Instructions
Apply power to the unit and observe the LED lights on the control hub. Ensure the Power LED is
illuminated on the control hub.
Download the Wi-Fan app available at your smart device store.
Navigate to the WiFi settings utility on your smart device.
Select the WVC Hub to connect. The SSID will start with WV-xxx…, which matches the ID to the label.
The label is located on the inside of the hub’s front cover.
Enter the default password to join the network. The default password is myfan.
Launch the Wi-Fan app to begin the pairing process.
For additional help: See the tutorial section in the Wi-Fan app.
Operating Instructions
Whole House Fans cool your home by pulling in fresh, cooler air from outside through open windows and doors.
For best results in a multi-story home, windows should be opened on alternate levels for most efficient cooling.
NEVER operate fan without open windows or doors.
CAUTION: If your home has a fireplace, be sure that the flue damper is closed to prevent chimney soot
from being drawn into the house by the fan. DO NOT operate the fan when a fire is burning in the
fireplace.
Common Installation Issues
Motor Stops after 10-20 Minutes
A tight belt tension can cause the unit to overheat.
Insufficient intake or exhaust Net Free Air. Open more doors and windows or increase the amount of ventilation in
the attic.
Check the bearing assembly for resistance on belt driven models to ensure there are no rough spots.
Unit is Noisy
If the unit is considered to be too noisy in general, install the additional frame between the fan and mounting frame.
Large fans will make noise while operating. Moving the fan further into the attic will reduce the apparent noise.
Make sure you still have 36 of clearance to the roof.
Make sure all screws and bolts are tightened.
Ensure enough clearance above the unit, minimum of 36” from fan blades to roof.
Verify Exhaust NFA. Inadequate NFA will result in the unit working harder and making more noise.
Not Enough Airflow
Verify NFA intake and exhaust requirements are being met. Lack of airflow can be the result of lack of fresh air and
lack of ventilation to expel the air. Try channeling the air by opening only doors and windows in a certain area to
funnel the wind flow.
Shutter is Hitting the Fan
Check to make sure there is enough space between the louvers and the fan. There should be around 6”-7 ½” between
the fan blade and the vent.