Use and Care Manual

Phone: (317) 577-0417
Email: sales@cool-space.com
Fax: (317) 485-0118
Call Today!! 1(800) 557-5716
TECHNICAL SUPPORT LINE: 1-800-557-5716
Visit www.cool-space.com for all Product information
Do’s & Don’ts
DO
Read the Owner’s Manual.
Check all hose connections.
Use a 12 gauge cord if under 50ft. or use 10 gauge cord if over 50ft..
Provide fresh air intake for the COOL-SPACE™.
Keep 3ft. minimum clearance behind the COOL-SPACE.
Flush new cooling media:
Fill the COOL-SPACE™ with water
Switch on the pump
Run without the fan for at least 5 hours
Use Proper FAN START UP procedures:
Turn fan switch to HIGH speed
Allow for maximum speed
Set at desired speed
Make sure the cooling media is being evenly saturated by using the control valve to adjust the water ow.
Drain and clean weekly. (Various conditions determine the need for this maintenance.) Remove cooling
media and wash with a garden hose.
Use Refresh Tablets (algae killer) and/or CTT-EC Cooler Treatment Tablets (mineral treatment).
ENJOY
DON’T
Don’t forget to dry out the pads before shutting down. Turn o the pump and leave fan funning for 10-15
minutes.
Don’t run the pump without rst lling the reservoir with water.
Don’t turn water valve all the way open - it may ood the cooling media.
Don’t operate with more than 120lbs. of water pressure.
Don’t operate the COOL-SPACE in a sealed room. Allow for fresh air intake and exhaust.
Don’t hesitate to call with any questions.

Summary of content (2 pages)