COMMERCIAL REFRIGERATOR AND FREEZER USER'S MANUAL Horizontal Bottle Coolers Model: JBC-65-HC JBC-95-HC PLEASE READ THE MANUAL THOROUGHLY PRIOR TO EQUIPMENT SET-UP, OPERATION AND MAINTENANCE,
Horizontal Bottle Coolers INSTALLATION/ OPERATION IMPORTANT! PLEASE READ BEFORE INSTALLATION 8 If the unit has recently been transported please let unit stand stilt fora minimum of 24 hours before plugging tin. B Make sure that the unit drops down to desired temperature before loading the unit with product. # Make sure that there is proper ventilation around the unit in the area where it will operate. B Make sure all accessories are installed (i.e. shelves, shelf clips, casters) before plugging the unit in.
Horizontal Bottle Coolers TEMPERATURE CONTROLS The temperature controls are factory-set to maintain an average temperature refrigerators. To maintain a different temperature, simply adjust the control knob located inside the unit. To decrease the temperature (colder) turn clockwise. To increase the temperature (warmer), turn counter-clockwise see diagram LOADING PRODUCT The bin dividers have been installed at the factory for your convenience. Feel free to reposition the dividers as you see fit.
Horizontal Bottle Coolers Do not load Product above the top crossbar. Dong so will harm the Refrigeration. SAFETY / WARNING Pleas pay close attention the safety notices in this section. Disregarding these notices may lead to serious injury and/or damage to the unit. ATTENTION ® To minimize shock and fire hazards; be sure not to overload outlet. Please designate one outlet for your unit. B Do not use extension cords. ® Do not put your hands under the unit when the unit is required to be moved.
Horizontal Bottle Coolers with wet hands. During maintenance and cleaning, please unplug the unit. PROPER GROUNDING REQUIRED To minimize shock and fire hazards, make sure that the unit is properly grounded. PROHIBITION # Do not pattern fo remove or repair any component unison instructed by factory. Make sure that the unit is not resting on or against the electrical cord and plug. To minimize personal injury, do not hang on the doors. Do not store any flammable and explosive gas or liquids inside the unit.
Horizontal Bottle Coolers REGULAR MAINTENANCE CLEANING THE CONDENSER COIL B For efficient operation, it is important that the condenser surface be kept free of dust, dirt, and lint. B We recommend cleaning the condenser coll and ding at least once per month. B Clean with a commercial condenser coil cleaner, available from any kitchen equipment retailer. Brush the condenser fins from tep to bettor, not side to side. B After cleaning, straighten any bent condenser ding with a fin comb.
Horizontal Bottle Coolers SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Compressor not |Fuse blown or circuit breaker Replace fuss or reset circuit running. tripped. breaker. Power cord unplugged. Plug in power cord. Thermostat set too high. Bet thermostat to lower temperature. Cabinet in defrost.cycle. Wait for defrost cycle to finish. Condensing unit | Excessive amount of warm Allow adequate time for rung for jog | product placed in cabinet. product {o cool down. periods of time.
Cabinet is noisy. Loose part(s). Turing vibration. Notate and frighten loose part(s}.