Product Manual

Page 3
3.0 SETUP
3.2 CONNECTING THE ELECTRICAL SUPPLY
IMPORTANT
The COOL-SPACE unit should be plugged into a fused or circuit breaker
protected 15 amp, 120 volt, and 60 Hz circuit.
All models utilize standard 120-volt power supply. The
unit should be plugged into a fused or circuit breaker
protected 15 amp, 120 volt, 60 Hz circuit.
Table 1 shows the amperage requirements for the
specific models. If an extension cord is required, refer
to Table 2 for the proper 3-conductor heavy-duty cord
required.
!
CAUTION
Do not exceed amperage ratings of the extension cord. Undersized
extension cords result in excessive drops in voltage, causing the electric
motor to generate excessive heat. This condition results in inefficient
motor operation and premature motor failure. This will void the
warranty.
AMPERAGE REQUIREMENTS
MODEL VOLTS ± 10% FREQUENCY (Hz) RUNNING AMPS
CS6-210 120 60 1.24
CS6-210-HV 120 60 2.04
Table 1: Electrical Requirements
3CONDUCTOR HEAVY DUTY EXTENSION CORD REQUIREMENTS
LENGTH (Ft)
CORD SIZE
16 GA 14 GA 12 GA 10 GA
0-50 13 A 18 A 25 A 30 A
50-100 10 A 13 A 18 A 25 A
Table 2: Cord Size Requirements