Technical Data 4395
Effective February
2018
Supersedes May 2017
Product features
Agency information
UL Listed, Guide JDYX, File E19180, 63mA-6.3A
UL Recognized Card: (7A-10A) Guide JDYX2, File E19180
CSA Certified, Class 1422-01, File E65063, 63mA-6.3A
MITI Approval, 1A-10A
KC-Mark: Certificate SU05011-4001 (63mA~250mA);
SU05011-4002 (300mA~800mA); SU05011-4003 (1A~3.15A);
SU05011-4004 (3.5A~6.3A)
Ordering
Specify packaging code prefix, product number and option
code suffix
GMC
5 mm x 20 mm Medium time-delay glass tube fuses
Medium time-delay, low breaking capacity
Available with optional axial leads
5 mm x 20 mm physical size
Glass tube, nickel-plated brass endcap construction
Designed to UL/CSA 248-14
Pb
HALOGEN
HF
FREE
Electrical Characteristics
Rated Current % of Amp Rating Opening Time
100% None
63mA - 10A 135% 60 minutes maximum
200% 2 minutes maximum
Voltage Typical DC Cold Typical Maximum
Product Rating Interrupting Rating (Amps)* Resistance Pre-Arc I
2
t Voltage
Number Vac 250Vac 125Vac ()**
AC
Drop (mV)
GMC-63-R
250 35 10,000 10.350 0.0027 1400
GMC-80-R
250 35 10,000 - 0.0050 1400
GMC-100-R
250 35 10,000 4.775 0.0094 1200
GMC-125-R
250 35 10,000 3.400 0.014 1000
GMC-150-R
250 35 10,000 2.555 0.022 800
GMC-160-R
250 35 10,000 2.295 0.022 730
GMC-200-R
250 35 10,000 1.395 0.032 650
GMC-250-R
250 35 10,000 0.965 0.046 490
GMC-300-R
250 35 10,000 0.838 0.081 580
GMC-315-R
250 35 10,000 0.685 0.081 480
GMC-400-R
250 35 10,000 0.615 0.18 510
GMC-500-R
250 35 10,000 0.335 0.41 370
GMC-600-R
250 35 10,000 0.282 0.60 360
GMC-630-R
250 35 10,000 0.246 0.66 360
GMC-700-R
250 35 10,000 0.213 0.85 340
GMC-750-R
250 35 10,000 0.213 0.85 320
GMC-800-R
250 35 10,000 0.180 0.85 290
GMC-1-R
250 35 10,000 0.156 1.8 250
GMC-1.25-R
250 100 10,000 0.098 3.4 200
GMC-1.5-R
250 100 10,000 0.076 5.4 190
GMC-1.6-R
250 100 10,000 0.067 5.8 160
GMC-2-R
250 100 10,000 0.043 8.9 130
GMC-2.5-R 250 100 10,000 0.035 13 130
GMC-3-R
250 100 10,000 0.026 19 130
GMC-3.15-R
250 100 10,000 0.025 23 130
GMC-3.5-R
125 - 10,000 0.022 25 130
GMC-4-R
125 - 10,000 0.019 36 120
GMC-5-R
125 - 10,000 0.014 58 120
GMC-6-R
125 - 10,000 0.013 88 120
GMC-6.3-R
125 - 10,000 0.012 110 120
GMC-7-R
125 - 200 0.012 150 120
GMC-8-R
125 - 200 0.009 200 110
GMC-10-R 125 - 200 0.007 300 110
* Interrupting ratings: Interrupting ratings for 63mA - 6.3A were measured at 70% - 80% power factor on AC.The interrupting ratings for 7A - 10A were measured at 100% power factor on AC.
** DC Cold Resistance (Measured at <10% of rated current)
Typical Pre-Archin
2
tg ( II
2
t was measured at listed interrupting rating and rated voltage)
Maximum Voltage drop (Voltage drop was measured at 20°C ambient temperature at rated current)

Summary of content (2 pages)