Cut Sheet
540
4C
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright
©
2013 Eaton’s Crouse-Hinds Business
Control Stations and their Sub-assemblies
Complete Control Station
Sub-assembly
Notes and RequirementsCover & Device Cast Back Box
MANUAL MOTOR STARTER
EFD218-T8 DSD916 EDS271
Alternative DS415A & SQ D 2510 KO-1 EDS271 SQ D switch provided by distributor
EFDC218-T8 DSD916 EDSC271
Alternative DS415A & SQ D 2510 KO-1 EDSC271 SQ D switch provided by distributor
EFD2419 DSD917 EDS271
Alternative DS415A & GE 2368S EDS271 GE switch provided by distributor
EFDC2419 DSD917 EDSC271
Alternative DS415A & GE 2368S EDSC271 GE switch provided by distributor
SNAP SWITCHES
EDS2129 DS652 & SW5 EDS271
Alternative DSD933 EDS271 External Sealing Fitting Required
EDSC2129 DS652 & SW5 EDSC271
Alternative DSD933 EDSC271 External Sealing Fitting Required
EDS218 DS652 & SW6 EDS271
Alternative DSD634 EDS271 External Sealing Fitting Required
EDSC218 DS652 & SW6 EDSC271
Alternative DSD634 EDSC271 External Sealing Fitting Required
EDS2130 DS652 & SW7 EDS271
Alternative DSD936 EDS271 External Sealing Fitting Required
EDSC2130 DS652 & SW7 EDSC271
Alternative DSD936 EDSC271 External Sealing Fitting Required
EDS2140 DS652 & SW8 EDS271
Alternative DSD937 EDS271 External Sealing Fitting Required
EDSC2140 DS652 & SW8 EDSC271
Alternative DSD937 EDSC271 External Sealing Fitting Required
EDS2229 (2) DS652 & (2) SW5 EDS272
Alternative (2) DSD933 EDS272 External Sealing Fitting Required
EDSC2229 (2) DS652 & (2) SW5 EDSC272
Alternative (2) DSD933 EDSC272 External Sealing Fitting Required
EDSC228 (2) DS652 & (2) SW6 EDSC272
Alternative (2) DSD634 EDSC272 External Sealing Fitting Required
EDS2230 (2) DS652 & (2) SW7 EDS272
Alternative (2) DSD936 EDS272 External Sealing Fitting Required
EDSC2230 (2) DS652 & (2) SW7 EDSC272
Alternative (2) DSD936 EDSC272 External Sealing Fitting Required
EDSC2240 (2) DS652 & (2) SW8 EDSC272
Alternative (2) DSD937 EDSC272 External Sealing Fitting Required
ROCKER SWITCHES
EDS2596 DSD949 EDS271
EDSC2596 DSD949 EDSC271
EDS2162 DSD951 EDS271 Start/ Stop Legend included
EDSC2162 DSD951 EDSC271 Start/ Stop Legend included
EDS2194 DSD950 EDS271
EDSC2194 DSD950 EDSC271
EDS2696 (2) DSD949 EDS272 Start/ Stop Legend included
EDSC2696 (2) DSD949 EDSC272 Start/ Stop Legend included
EDS2262 (2) DSD951 EDS272
EDSC2262 (2) DSD951 EDSC272
EDS2294 (2) DSD950 EDS272
EDSC2294 (2) DSD950 EDSC272
Additional notes:
• See Eaton's Crouse-Hinds' installation instructions for any possible additional sealing requirements.
• Part numbers listed with
3
/4" hub in back box (Ex. EDS2184). For
1
/2" hub, change the "2" to "1" (EDS1184). For 1" hub, change the "2" to "3" (EDS3184).
• Control Stations with "Stop" legend have lockout provided as standard.
• Pilot Light Colors J*-- J1= Red, J3= Green, J6= Amber, J10= Clear, J11= Blue. LED pilot lights are available with LED suffix.
• Pilot Light Transformers for voltages over 125V. Suffix T2= 240/220 - 110V, T4= 480/440 - 110V, T5= 600/500 - 110V (not available on double pilot cover).
• Standard legend plate markings are available by adding nomenclature after the part number (EDS2184-Run).
• Selector switch nameplate kits available. 2-Pos = "SS2KIT", 3-Pos = "SS3KIT". See Replacement Parts book for additional information.
• Copper-free aluminum bodies and covers available with SA suffix.
• Additional control station options may be found in Section 4C.
• Group B ratings may be achieved by adding the GB suffix or using the EFS back box. See part number instructions for the item required.
• Group B ratings may already be achieved when used in Class I, Division 2 applications. See Certifications and Compliances for item required.
• Additional control station configurations available through the FlexStation Component Series.
4C
EDS / EFS Series Control Stations
Sub-assembly
Reference Guide
For a complete list of components for
EDS & EFS Control Stations, see page 514
for FlexStation™ Series