Cut Sheet
4C
546
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright
©
2013 Eaton’s Crouse-Hinds Business
Ordering Information - Combination Control Stations
Enclosure With Pushbuttons and Pilot Lights
Pilot
Lights* Pushbuttons Diagram Markings
Hub
Size Volts
Dead End
Cat. #
Through Feed
Cat. # Volts
Dead End
Cat. #
Through Feed
Cat. #
11
Specify
1
/
2
120
N2S12411 ➀➁ N2SC12411 ➀➁
480
N2S12414 ➀➁ N2SC12414 ➀➁
3
/4 N2S22411 ➀➁ N2SC22411 ➀➁ N2S22414 ➀➁ N2SC22414 ➀➁
1 N2S32411 ➀➁ N2SC32411 ➀➁ N2S32414 ➀➁ N2SC32414 ➀➁
1
/2
240
N2S12412 ➀➁ N2SC12412 ➀➁
600
N2S12415 ➀➁ N2SC12415 ➀➁
3
/4 N2S22412 ➀➁ N2SC22412 ➀➁ N2S22415 ➀➁ N2SC22415 ➀➁
1 N2S32412 ➀➁ N2SC32412 ➀➁ N2S32415 ➀➁ N2SC32415 ➀➁
12
Specify
1
/2
120
N2S13421 ➀➁ N2SC13421 ➀➁
480
N2S13424 ➀➁ N2SC13424 ➀➁
3
/4 N2S23421 ➀➁ N2SC23421 ➀➁ N2S23424 ➀➁ N2SC23424 ➀➁
1 N2S33421 ➀➁ N2SC33421 ➀➁ N2S33424 ➀➁ N2SC33424 ➀➁
1
/2
240
N2S13422 ➀➁ N2SC13422 ➀➁
600
N2S13425 ➀➁ N2SC13425 ➀➁
3
/4 N2S23422 ➀➁ N2SC23422 ➀➁ N2S23425 ➀➁ N2SC23425 ➀➁
1 N2S33422 ➀➁ N2SC33422 ➀➁ N2S33425 ➀➁ N2SC33425 ➀➁
21
Specify
1
/2
120
N2S13411 ➀➁ N2SC13411 ➀➁
480
N2S13414 ➀➁ N2SC13414 ➀➁
3
/4 N2S23411 ➀➁ N2SC23411 ➀➁ N2S23414 ➀➁ N2SC23414 ➀➁
1 N2S33411 ➀➁ N2SC33411 ➀➁ N2S33414 ➀➁ N2SC33414 ➀➁
1
/2
240
N2S13412 ➀➁ N2SC13412 ➀➁
600
N2S13415 ➀➁ N2SC13415 ➀➁
3
/4 N2S23412 ➀➁ N2SC23412 ➀➁ N2S23415 ➀➁ N2SC23415 ➀➁
1 N2S33412 ➀➁ N2SC33412 ➀➁ N2S33415 ➀➁ N2SC33415 ➀➁
22
Specify
1
/2
120
N2S14421 ➀➁ N2SC14421 ➀➁
480
N2S14424 ➀➁ N2SC14424 ➀➁
3
/4 N2S24421 ➀➁ N2SC24421 ➀➁ N2S24424 ➀➁ N2SC24424 ➀➁
1 N2S34421 ➀➁ N2SC34421 ➀➁ N2S34424 ➀➁ N2SC34424 ➀➁
1
/2
240
N2S14422 ➀➁ N2SC14422 ➀➁
600
N2S14425 ➀➁ N2SC14425 ➀➁
3
/4 N2S24422 ➀➁ N2SC24422 ➀➁ N2S24425 ➀➁ N2SC24425 ➀➁
1 N2S34422 ➀➁ N2SC34422 ➀➁ N2S34425 ➀➁ N2SC34425 ➀➁
Ordering Information - With Pushbuttons – Momentary Contact
Marking Unless
Enclosure with Pushbuttons
No.
Units Contact Symbol
Otherwise
Specified
Hub
Size
Dead End
Cat. #
Through Feed
Cat. #
1
START
(or Specify)
1
/2 N2S1110 ➁ N2SC1110 ➁
3
/4 N2S2110 ➁ N2SC2110 ➁
1 N2S3110 ➁ N2SC3110 ➁
2
START-STOP
(or Specify)
1
/2 N2S1210 ➁ N2SC1210 ➁
3
/4 N2S2210 ➁ N2SC2210 ➁
1 N2S3210 ➁ N2SC3210 ➁
3
Specify
1
/2 N2S1310 ➁ N2SC1310 ➁
3
/4 N2S2310 ➁ N2SC2310 ➁
1 N2S3310 ➁ N2SC3310 ➁
4
Specify
1
/2 N2S1410 ➁ N2SC1410 ➁
3
/4 N2S2410 ➁ N2SC2410 ➁
1 N2S3410 ➁ N2SC3410 ➁
4C
N2S and N2SC Series
Control Stations
Factory Sealed, Corrosion-Resistant
600VAC Heavy Duty
Cl. I, Div. 2, Groups B, C, D
NEMA 3, 4X, 7BCD (Div. 2), 12
Watertight
Weatherproof
Dust-tight
➀ See pages 545–547
➁ See pages 545–547
‡ Pilot lights are transformer type except those rated 120 volts. Lamp type is 120MB, 120 volts, 3 watts.