Brochure
CH-18MSPH230VO CH-28MSPH230VO CH-36MSPH230VO CH-48MSPH230VO
Power supply Ph-V-Hz 208-230V/60Hz, 1Ph 208-230V/60Hz, 1Ph 208-230V/60Hz, 1Ph 208-230V/60Hz, 1Ph
Cooling
Capacity Btu/h 17,000 27,000 36,000 48,000
EER Btu 12.5 12.0 10.9 11.6
SEER 21.3 22.0 22.5 21.5
Heating at 47°F
Capacity Btu/h 18,000 28,000 36,000 48,000
COP 3.7 3.7 3.1 3.4
HSPF4 10 9.8 10.3 10,4
HSPF5 8.6 8.0 9.0 8,6
Heating at 17°F Rated capacity Btu/h 11,800 16,800 25,400 30,800
Heating at 5°F/-15°C maximum capactiy Btu/h 14,279 20,966 28,800 35,860
Minimum Circuit Ampacity A 18.0 25.0 30.0 35.0
Max.Fuse A 25.0 35.0 45.0 50.0
Compressor
Type ROTARY ROTARY ROTARY Twin-ROTARY
Capacity Btu/h 15,388 24,345 32,380 38,214
Input W 1,17 2 3 3
Rated current(RLA) A 10 20 22 21
Refrigerant oil/oil charge ml VG74/500 POE(VG74)/670 PQE(VG74)/1000 Ester Oil VG74/1400
Outdoor fan motor
Input W 115 150 150 126
RLA A 0.74 0,9 1.3 0,39
Speed r/min
150/200/250/300/350/450/
550/650/800/850
150/200/250/300/400/500/
600/750/900/1000
150/200/250/300/400/500/
600/750/900/1000
150/200/250/300/400/
500/600/700/800/870
Outdoor air ow CFM 1390 2130 2130 4500
Outdoor noise level dB(A) 62,4 63,4 62,3 64
Outdoor unit
Dimension(WxDxH) in 33.27x14.29x27.64 37.24x16.14x31.89 37.24x16.14x31.89 37.48x16.34x52.48
Packing (WxDxH) in 37.99x15.55x30.12 42.91x19.69x34.45 42.91x19.69x34.45 43.11x19.49x58.27
Net/Gross weight lb 105.82/114.64 152.12/160.94 156.53/167.55 223.77/255.07
Refrigerant type oz R410A/70.5 R410A/98.8 R410A/105.8 R410A/162.3
Refrigerant precharge(Total pipe length) ft 25 25 25 25
Additional charge for each ft oz 0.16 0.16 0.16 0,32
Design pressure PSIG 550/340 550/340 550/340 550/340
Refrigerant piping
Liquid side/Gas side in 2 X (1/4" / 3/8") 3 X (1/4" / 3/8") 4x1/4"/3x3/8"+1x1/2" 5x1/4"/3x3/8"+2x1/2"
Max. length for all rooms ft 131 197 262 262
Max. length for one indoor
unit
ft 82 98 115 115
Max. height dierence
between indoor and outdoor
unit
ft 49 49 49 49
Max. height dierence
between indoor units
ft 33 33 33 33
Connection wiring NO NO NO NO
Ambient temperature
cooling F° -13~122 -13~122 -13~122 -13~122
heating F° -13~86 -13~86 -13~86 -13~86
Multi-Zone Inverter
Heat Pump Outdoor Unit
C&H SOPHIA Multi-Zone systems, with inverter
technology, are some of today’s most advanced
ductless split heat pumps.
Up to 5 indoor units can be connected to a single
outdoor unit, reducing the number of outdoor
units required.
All indoor units can be individually controlled and
do not need to be installed at the same time.