Spec Sheet

Table Of Contents
Submittal Data Sheet
CH-60LCDTU/I (INDOOR UNIT) CH-60LCU/O (OUTDOOR UNIT)
Job Name:_________________________________________________________________________
Location:______________________________________________________ __________________
Engineer:______________________________________________________________________
Submitted to:_____________________________________________________________________
Submitted by:_____________________________________________________________________
Reference:_________________________________________________________________________
Date:______________________________________________________________________________
Approval:__________________________________________________________________________
Сonstruction:______________________________________________________________________
Unit #:_____________________________________________________________________________
Drawing #:_________________________________________________________________________
OPERATION TEMPERATURE RANGE
ELECTRICAL
PIPING
Cooling
PERFORMANCE
AND
EFFICIENCY
Capacity
SEER
EER
Capacity
COP
HSPF4
HSPF5
cooling
heating
Indoor Outdoor
6290 3286
cooling heating
5122 586
62000
3.6
9.0
7.6
57000
18.0
10.0
Btu/h
Btu/h
W/W
Btu
Input 5700
W
Heating at 47F
Duct Light Commercial Series
Duct Air Conditioners
• Flexible Installation
• Fresh Air Function
• Wired Control & Wi-Fi Connection
• Multi-Channel Air Distribution
• Built-In Water Pump
• Golden fin for outdoor and indoor
• Lower Noise
• Higher Pipe Limits
• Slim Design
Sound Preassure level (Hi/Mi/Lo)
Design pressure
Dimension (W*D*H)
Net/Gross weight
57/54/51 dB(A)
550/340 PSIG
55x34x17 in
163/189.6 Lb
Refrigerant piping/Gas side in (3/8"3/4")
Max. pipe length ft 213
Max. difference in level ft 98
MCA: Minimum Circuit Ampacity; MFA: Max.fuse amps; RLA: Rated load amps
Power supply V/Hz/Ph 208-230V/ 60Hz/ 1Ph
MCA A 36
MFA A 50
Indoor fan motor
Outdoor fan motor
Compressor
Input
RLA
W 420
A 3.65
Input
RLA
W 126
A 1.2
Capacity
Input
Btu/h 44697
W 3420
RLA A 23.5
GENERAL FEATURES
INDOOR SPECIFICATION
Air flow
Noise level
Dimension (W*D*H)
Net/Gross weight
4414
64.0
37.48x16.34x52.48
224.9/254.4
Refrigerant Type
Refrigerant precharge
Additional charge for each ft
R410/163
25
0.32
CFM
dB(A)
in
Lbs
ft
oz
OUTDOOR SPECIFICATION
This warranty should be registered on our web-site www.cooperandhunter.us
within 60 days of installation. The warranty is only valid when installed by
a Licensed HVAC Technician. A warranty period of Seven (7) years on compres-
sor to the original registered end-user. A warranty period of Five (5) years on all
parts to the original registered end user. Warranty applies only to products
remaining in their original installation location.

Summary of content (2 pages)