Spec Sheet
This warranty should be registered on our web-site
www.cooperandhunter.us within 60 days of installation.
The warranty is only valid when installed by a Licensed HVAC
Technician. A warranty period of Seven (7) years on compressor
to the original registered end-user. A warranty period of Five (5)
years on all parts to the original registered end user. Warranty
applies only to products remaining in their original installation
location.
GENERAL FEATURES
• Golden n and indoor
• Heat pump units can heat & cool up to 5 zones
• Turbo Operation
• Auto-Restart
• Self Diagnosis Function
• Multi speed fan
• Auto protection
COMPATIBILITY
Connect 2 multiple style indoor units:
Wall mounted: 9K/12K
Cassette/Console: 9K/12K
OUTDOOR SPECIFICATION
Air ow 2130 CFM
Noise Level 63.4 dB(A)
Dimension (W*D*H) 37.24x16.14x31.89 in
Net/Gross weight 152.12/160.94 lb
Refrigerant type R410A/98.8 oz
Refrigerant precharge 50 ft
Additional charge for each ft 0.16 oz
PERFORMANCE AND EFFICIENCY
Cooling Heating
19,000 Btu/h 20,000 Btu/h
SEER 21.5 HSPF4/HSPF5 9.8/8.5
EER 12.5 COP 3.4
OPERATION TEMPERATURE RANGE
Ambient temperature
cooling heating
-22~122 -22~86
ELECTRICAL
Power supply 208-230V/ 60Hz, 1Ph
MCA 25 A
MFA 35 A
MCA: Minimum Circuit Ampacity MFA: Max. fuse A
PIPING
Refrigerant piping Liquid/Gas side 2x1/4" - 3/8"
Max. length for all rooms 131 ft
Max. length for one indoor unit 82 ft
Max. height dierence between indoor and outdoor unit 49 ft
Max. height dierence between indoor units 33 ft
WIRING
Connection wiring 16AWG*4 Stranded, unshielded
SUBMITTAL DATA SHEET CH-HYP19MSPH-230VO (OUTDOOR UNIT)
Job Name: ................................................................................................................................... Date: ...........................................................................................................................................
Lacation: ..................................................................................................................................... Approval: ....................................................................................................................................
Engineer:..................................................................................................................................... Construction: ...............................................................................................................................
Submitted to: .............................................................................................................................. Unit #: .........................................................................................................................................
Submitted by: ............................................................................................................................. Drawing #: ..................................................................................................................................
Reference: ...................................................................................................................................
SOPHIA Hyper