USER’S MANUAL PACKAGED TERMINAL AIR CONDITIONER WITH HEAT PUMP / HEAT STRIP Model: CH-PT09HPGF CH-PT09HSGF The warranty is only valid when installed by a LICENSED HVAC TECHNICIAN. F or proper operation, please read and keep this manual carefully. Designed by Cooper&Hunter International Corporation, Oregon, USA www.cooperandhunter.
CONTENTS 1. SAFETY PRECAUTIONS..................................................................2 2. IMPORTANT SAFETY INSTRUCTIONS ..........................................4 3. AIR CONDITIONER FEATURES.......................................................5 4. CONTROL PANEL OPERATION.......................................................6 5. INSTALLATION .................................................................................7 6. CARE AND CLEANING...................................................
SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. ! WARNING This symbol indicates the possibility of death or serious injury. ! CAUTION This symbol indicates the possibility of injury or damage to property. Meanings of symbols used in this manual are as shown below. Never do this.
! CAUTION Do not clean the air conditioner with water. When the air filter is to be removed, do not touch the metal parts of the unit. It may cause an injury. ! When the unit is to be cleaned, switch off, and turn off the circuit breaker. Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury. ! Stop operation and close the window in storm or hurricane. Operation with windows opened may cause wetting of indoor and soaking of household furniture.
IMPORTANT SAFETY INSTRUCTIONS WARNING NOTE The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section Operation , of Current Device for details. In the event that the power supply cord is damaged, it cannot be repaired-it must be replaced with a cord from the Product Manufacturer. , Do not, under any circumstances, cut, remove, or bypass the grounding prong.
Operation of Cur rent Device(optional) The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following: 1. Plug in the Air Conditioner. 2. The power supply cord will have TWO buttons on the plug head. Press the TEST button, you will notice a click as the RESET button pops out. 3. Press the RESET button, again you will notice a click as the button engages. 4. The power supply cord is now supplying electricity to the unit.
CONTROL PANEL OPERATION The control panel keypad will look like the following Fig.1: UP/DOWN BUTTONS ( / ) - Push the UP (or DOWN) button to increase (or decrease) the set temperature of the unit in cooling or heating mode.The temperature can be set by increments of 1OC (1OF).The setting temperature appears in the display. NOTE:Press and hold and buttons together for 3 seconds will alternate the temperature display between OC & OF scale. Fig.1 POWER - Press the POWER button to turn the unit on or off.
INSTALLATION HOW TO INSTALL THE UNIT Dimension of air conditioner ! CAUTION 1067mm/4 2in ch There are sharp edges that can cause serious cuts. When lifting the air conditioner,it is HEAVY.Use 2 people to lift. 408mm/1 6in ch - For existing sleeve,you should measure the wall sleeve dimensions. - Install the new air conditioner according to these installation instructions to achieve the best performance.
INSTALLATION(CONTINUED) UNIT INSTALLATION (CONTINUED) - Rotate the vent control lever to either open or close the vent door.(See Fig.6) Vent control lever Vent closed Vent open Fig.6 NOTE:When vent control lever set at CLOSE,only the air inside the room is circulated and filtered. When set at OPEN,some outdoor air will be drawn into room.This will reduce heating or cooling efficiency.
CARE AND CLEANING FRONT PANEL AND CASE - Turn unit off and disconnect power supply.To clean, use water and a mild detergent.DO NOT use bleach and abrasivers.Some commercial cleaners may damage the plastic parts. OUTDOOR COIL - Coil on outdoor side of unit should be checked regularly.Unit will need to be removed to inspect dirt build-up that will occur on the inside of the coil. If clogged with dirt and soot ,coil should be professionally cleaned.Clean inside and outside of outdoor coils regularly.
TROUBLESHOOTING POSSIBLE CAUSES UNIT DOES NOT START Unit may have become unplugged Fuse may have blown Circuit breaker may have been tripped Unit may be off Unit may be in a protection mode. UNIT NOT COOLING/HEATING ROOM Unit air discharge section is blocked Temperature setting is not high or low enough Note:Setpoint limits may not allow the unit to heat or cool the room to the temperature desired.Check section on dipswitch settings. Unit air filters are dirty.
www.cooperandhunter.us LIMITED WARRANTY STATEMENT PACKAGED TERMINAL AIR CONDITIONER This warranty should be registered on our web-site www.cooperandhunter.us The warranty is only valid when installed by a Licensed HVAC Technician FOR WARRANTY SERVICE OR REPAIR: Contact your installing contractor. You may find the installer’s name on the equipment or in your Owner’s packet. Complete product registration below and send back by e-mail at warranty@cooperandhunter.us PRODUCT REGISTRATION: Model No.
LIMITATIONS OF WARRANTIES: ALL IMPLIED WARRANTIES AND/OR CONDITIONS (INCLUDING IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE OR PURPOSE) ARE LIMITED TO THE DURATION OF THIS LIMITED WARRANTY. SOME STATES OR PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY OR CONDITION LASTS, SO THE ABOVE MAY NOT APPLY TO YOU.