Installation Instructions

11
www.eaton.com/wireless
call toll free: 1-800-663-8806 DMAN-4077-01 R01
Service Mode
Service Mode is available on all TD110 configurations and allows the operator to pair to base station, adjust the
RCUs timeout and run diagnostics.
Once the RCU has entered into service mode, navigation and option selection/modification is controlled by four
buttons as described by the Enter Service Mode and Navigation sections below.
Enter Service Mode
A. Press and Hold Power OFF [RED]
B. Press and Hold Power ON
[GREEN]
Wait for the COMM LED to be turned ON, then immediately
proceed to next step.
C. Release Power OFF
[RED]
D. Release Power ON
[GREEN]
The COMM LED
will blink YELLOW when unit enters service
mode.
If no buttons are pressed within 5 minutes after entry to service
mode, the RCU will automatically turn OFF.




A.
B
.
C.
D.
Navigation
Once you have entered service mode you can select the service
mode options listed below
The Power ON
[GREEN] will allow you to execute or modify an
option. Power OFF
[RED] will allow you to move up from an
entry and power off the unit. Only one option is allowed at a time in
service mode. Service mode options are listed below
A. Button
[GREEN] - Start pairing TD110
B. Button
- Modify RCU timeout
C. Button
- Run Diagnostics
D. Button
- Software build version




COMM LED