Product Guide

19
www.eaton.com/wireless
call toll free: 1-800-663-8806 DMAN-4096-01 R1
Service Mode: Field Configuration
Configuring RCU / Base Station Outputs in the Field
A field configurable system maps the 16 sixteen function buttons to the first 16 R160 Base Station outputs. The config-
uration determines the function of each Base Station output and allows customization as Momentary, Latched or Main-
tained. Button pairs on the same row may also be interlocked, preventing the two functions from activating at the same
time.
The 18-digit Configuration Code contains all the information necessary to customize the TS110 / R160 system. Each
digit, indicated by a number or letter, represents a specific functional option available for each Base Station output.
Refer to the Output Function Selection Table below for help determining a Configuration Code. Choose one option
for each digit and use the resulting 18-digit Configuration Code in step 3 of the Changing the Configuration proce-
dure on the next page.
Option Output Description
1
Momentary / Normal ON
2
Momentary / Normal OFF
3
Latched / Normal ON
4
Latched / Normal OFF
5
Maintained / Normal ON / Interlocked with paired output *
6
Maintained / Normal OFF / Interlocked with paired output *
7
Momentary / Normal ON / Interlocked with paired output *
8
Momentary / Normal OFF / Interlocked with paired output *(DEFAULT)
9
Maintained / Interlocked with paired output * (0.5 sec. delay)
A
Maintained / Interlocked with paired output * (2.0 sec. delay)
B
Latched / Normal OFF / Interlocked
C
Latched / Interlocked with paired output * (0.5 sec. delay)
D
Latched / Interlocked with paired output * (2.0 sec. delay)
Table 1 - Output Function Selection Table
* Paired outputs must use the same number code
Configuration Code (first group - 10 digits)
Record the first group of 10 digits of the Configuration Code below
5 1
Output 1 Output 3 Output 5
Output 2 Output 4 Output 6 Output 8
5 1 8 8 8 8 8 8 8 8
Paired Paired Paired Paired
Configuration Code (second group - 8 digits)
Record the remaining 8 digits of the Code below
Output 9
Output 11
Output 13
Output 15
Output 10 Output 12 Output 14 Output 16
8 8 8 8 8 8 8 8
Paired
Paired Paired Paired
Output 7
NOTE: Only properly equipped R160 Base Stations may be configured in the field.