Owner manual

DFI INFINITY CS (V- M3598/N/0906) 26 CF 70
MENU X/TARE S/NT/GRS
R.1=
(Ratiometric Reading)
(Non-ratiometric reading)
R.2=
(1µV resolution for unipolar & 5µV
resolution for bipolar)
(2µ V resolution for unipolar & 10µV
resolution for bipolar)
(3µ V resolution for unipolar & 15µV
resolution for bipolar)
(5µ V resolution for unipolar & 25µV
resolution for bipolar)
(10µ V resolution for unipolar & 25µV
resolution for bipolar)
Note: 3 µV resolution means if your input is 0-30mV,
at 30mV the display shows 9999.
R.3=
(Filtered value)
(Unfiltered value)
Reading Configuration
R.4=
(Gross/Net Display)
(Peak Display)
Display Color Selection
Show input choices:
Green
Red
Amber
S.1=
(Active above)
(Active below)
S.2=
(Unlatched)
(Latched)
Setpoint 1 Configuration
S.3=
(Net Reading)
(Gross Reading)
S.1=
(Active above)
(Active below)
S.2=
(Unlatched)
(Latched)
Setpoint 2 Configuration
S.3=
(Net Reading)
(Gross Reading)
Setpoint 1 Deadband
Press to scroll to the next
digit to the right.
Press to change the value of the flashing digit.
Setpoint 2 Deadband
Press to scroll to the next
digit to the right
Press to change the value of the flashing digit