Owner's manual
CF 189  5  Rev. E; Dec. 12, 2011 
EMI / EMC   Unit Value
 Tested Standards     
23  EN 61000-6-3: 2007  -  PASSED 
24  EN 55011: 2009 + A1: 2010 class B  -  PASSED 
25  EN 61000-6-2: 2005  -  PASSED 
26  EN 61000-4-2 (ESD) : 2009  -  PASSED 
27  EN 61000-4-3 (HF) : 2006 + A1: 2008 + A2: 2010  -  PASSED 
28  EN 61000-4-4 (BURST): 2004 + A1: 2010  -  PASSED 
29  EN 61000-4-5 (Surge): 2006  -  PASSED 
30  EN 61000-4-6: 2009  -  PASSED 
31  EN 61000-4-8: 2010  -  PASSED 
32  EN 61000-4-11: 2004  -  PASSED 
Load limits
4)
  Unit  Value  
33  Maximum measurable torque  %  110 
34  Maximum torque, related to nominal torque  %  300 
35  Ultimate torque  %  500 
36  Maximum load of key stone (Application factor 1,5)  %  180  200  200 
4)  Based on the non-contact measurement principle the torque sensor is quite insensitive to bending 
and shearing forces. Self-aligning couplings are recommended in case of dynamic loads. 
4.0 VERSIONS AND ORDER OPTIONS 
LXT 980 Accuracy 0.2% 
LXT 981 Accuracy 0.1% 
Option 1: Measurement range
     5 0  Nm 
     1 0 0  Nm 
     2 5 0  Nm 
     5 0 0  Nm 
    1 0 0 0  Nm 
    2 0 0 0  Nm 
Option 2: Angle sensor
  0 without angle sensor 
        1  with angle sensor 360 P / Rev. (optical) 
Option 3: Output signal
5)
    A analog voltage output 
            S  additional current output 4-20mA 
    P additional PWM output 
            F  additional Frequency output 20-100kHz 
Option 4: Shaft ends
6)
                0  Standard round shaft ends with key stone 
      1 Square shaft ends 
      2 Hexagon shaft ends 
Option 5: Protection class 
        0  IP50 
        1  IP64 (without angle sensor) 
5)  Only the analog voltage output is calibrated by default. All other output signals are adjusted according 
to the analog voltage output. 
6)  The square and hexagon shaft ends are not in stock. They must be ordered separately first and their 