Owner's manual
CF 189  6  Rev. E; Dec. 12, 2011 
5.0 AVAILABLE OPTIONS 
5.1 Optional Signal Outputs 
In addition to the analog output signal the LXT 980 and LXT 981 can also be delivered with another 
option output signal as listed below. 
Frequency Output 
Description  Unit  Value 
Basic frequency  kHz  60 
Measurement range  kHz  20… 100 
Calibration parameter  kHz/Nm  40 / measurement range 
Current output 
Description  Unit  Unit 
Signal at torque = zero  mA  12 
Measurement range  mA  4… 20 
Calibration parameter  mA/Nm  8 / measurement range 
PWM signal output     
Description  Unit  Unit 
Carrier frequency  Hz  980 
Signal at torque = zero  %  50 
Measurement Range  %  10… 90 
Error indication  %  95 
Calibration parameter  %Nm  40 / measurement range 
5.2 Optical angle sensor 