Manual
CF 187  5    RevA 
4.0 HARDWARE CONFIGURATION 
4.1 Connector Alignment  
As the MasterLink 3000 has been developed to provide a compact integration to connectorized strain gage 
transducers, the connector has the ability to rotate to a desired orientation for the application. The connector 
adapter is a pipe thread which screws into the connector plate block. To maintain the IP rating of the system, the 
connector must always be tightened into the block and not loosened. In order to tighten the connector, a wrench 
must used both on the connector plate block and the connector adapter. If for some reason the connector 
needs to be removed, the threads must be cleaned and a new layer of teflon tape must be used. 
4.2 Connector Wiring 
Pinout: 
1    Battery + (RED) 
2   Battery - (BLACK) 
3    -Excitation 
4    -Signal 
5    +Signal 
6   +Excitation 
CONNECTOR PLATE BLOCK 
6 5 4 3 2 1 