Indoor Furnishings User Manual

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
08/02/2008 1:17:50 PM
ADF023035
PHOTOMETRICS
2HB
C o e f c i e n t s o f U t i l i z a t i o n
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
Ty p i c a l VC P P e r c e n t a g e s
Height Along Height Across
Room Size (Ft.) 8.5’ 10.0’ 8.5’ 10.0’
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Z o n a l L u m e n S u m m a r y
Zone Lumens %Lamp %Fixture
0-30
0-40
0-60
0-90
0-180
C a n d e l a
Angle Along II 45° Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
2HB-454T5-UPL
Electronic Ballasts
(4) F54T5/830 HO
lamps
4400 lumens
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 1.2 x
mounting height
Efficiency 92.7%
Test Report:
2HB454T5UPL.IES
LER =69
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.48
5108 5108 5108
5058 5272 5533
4983 6118 7612
4860 7745 8477
4687 8179 7737
4466 7661 6119
4197 6528 4015
3888 5019 2272
3535 3222 2136
3150 1901 2143
2729 1737 2136
2285 1672 2121
1836 1601 2128
1397 1533 1993
975 1464 1606
600 1124 1553
302 968 1189
92 432 317
2 10 11
109 109 109 109 106 106 106 106 101 101 101 96 96 96 91 91 91 89
101 97 93 90 98 94 91 88 90 87 85 85 83 81 81 80 78 76
93 86 80 75 90 84 78 74 80 75 72 76 73 69 73 70 67 65
85 77 70 64 83 75 69 63 72 66 62 69 64 60 66 62 59 57
79 69 61 56 77 67 60 55 64 59 54 62 57 53 60 55 52 50
73 62 54 48 70 60 53 48 58 52 47 56 50 46 54 49 45 43
67 56 48 42 65 55 47 42 53 46 41 51 45 41 49 44 40 38
62 51 43 38 61 50 43 37 48 42 37 46 41 36 45 40 36 34
58 46 38 33 56 45 38 33 44 37 33 42 36 32 41 36 32 30
54 42 34 29 52 41 34 29 40 33 29 38 32 38 37 32 28 26
50 38 31 26 49 37 31 26 36 30 26 35 29 25 34 29 25 23
5533 31.4 33.9
8327 47.3 51.0
12541 71.3 76.9
15612 88.7 95.7
16318 92.7 100.0
45 51 35 46
36 41 23 30
33 36 16 18
33 38 26 33
29 32 19 19
C o e f c i e n t s o f U t i l i z a t i o n
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
Ty p i c a l VC P P e r c e n t a g e s
Height Along Height Across
Room Size (Ft.) 8.5’ 10.0’ 8.5’ 10.0’
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Z o n a l L u m e n S u m m a r y
Zone Lumens %Lamp %Fixture
0-30
0-40
0-60
0-90
0-180
C a n d e l a
Angle Along II 45° Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
2HB-454T5-G-UPL
Electronic Ballasts
(4) F54T5/830 HO
lamps
4400 lumens
Spacing criterion:
(II) 1.3 x mounting
height, ( ) 1.4 x
mounting height
Efficiency 99.3%
Test Report:
2HB454T5G.IES
LER =74
Yearly Cost of 1000
lumens, 3000 hrs
at .08 KWH = $3.23
5064 5064 5064
5041 5072 5100
4982 5085 5176
4885 5092 5168
4745 5015 5073
4565 4870 4906
4347 4667 4699
4094 4407 4514
3807 4118 4365
3487 3841 4206
3135 3588 4004
2752 3322 3741
2339 3025 3417
1895 2667 2950
1426 2265 2283
953 1619 1981
516 1214 1333
148 436 308
0 0 0
118 118 118 118 115 115 115 115 110 110 110 106 106 106 101 101 101 99
108 103 99 95 105 101 97 93 96 93 90 93 90 87 89 87 85 83
98 89 82 77 95 87 81 76 84 79 74 81 76 72 78 74 71 68
89 78 70 64 87 77 69 63 74 67 62 71 66 61 69 64 60 58
81 69 60 53 79 68 60 53 65 58 52 63 57 52 61 55 51 49
74 61 51 45 72 60 51 44 57 50 44 55 49 43 54 48 43 41
68 54 45 38 66 53 44 38 51 43 38 50 43 37 48 42 37 35
62 48 39 33 61 48 39 33 46 38 33 44 38 32 43 37 32 30
57 43 34 28 56 43 34 28 41 33 28 40 33 28 39 32 28 26
53 39 30 24 51 38 30 24 37 29 24 36 29 24 35 28 24 22
49 35 27 21 48 35 27 21 34 26 21 33 26 21 32 25 21 19
30 38 23 31
24 27 17 21
22 24 14 15
24 28 21 24
22 23 17 16
4134 23.5 23.7
6882 39.1 39.4
12836 72.9 73.5
17469 99.3 100.0
17469 99.3 100.0
No internal fixture
access required for
installation or
disconnecting power.
Code Compliance
UL/cUL Certified for Make/Break
under load (UL2549)
Meets NEC requirements for
ballast disconnect (NEC 410.73G)
Allows for addition of Occupancy
Sensor without hard connections
Receptacles complete with
insulating dustcap
Cooper Lighting’s F-Bay Modular Power Supply option allows external fixture access for safe and easy servicing. There is no need
to remove lamps or reflectors to disconnect fixture power with F-Bay Modular Power Supply. Access to the individual fixtures
power supply allows servicing without turning off all the fixtures disrupting occupants. F-Bay Modular Power Supply is a time
saver in installation – simply plug & power.
1 2
Modular F-Bay Power Supply
1. Modular Power Supply Receptacle supplied
mounted into fixture Access Plate.
2. Modular Power Cord & Plugs in 120, 277, 347,
& 480V configurations for easy plug & power
into existing supply.
Modular Motion Sensor Option
supplied with Mounting Box and
Modular Power Supply Receptacle.