User guide

7510r Programming Reference - System Options
Page 43
Stray on Entry Delay
To determine what the system will do if a user strays
from an entry route zone during entry select
System
Options, Stray on ent Dly. (This option is available to
provide compliance with EN 50131-1.)
Select Disabled to make the system give an alarm
immediately if the user strays from an entry route zone
during entry.
If you select Enabled and the user strays from an entry
route zone during entry then the system waits 30
seconds before raising a full alarm. The system also gives
an internal alarm during the 30 second wait.
If the user enters an access code or presents a tag before
the end of the 30 seconds internal alarm then the user
can reset the system.
Supervision
If the alarm system must meet EN50131-3 radio
supervision requirements then select
System Options
,
Supervision
and enable Supervision. Once enabled, the
control unit will prevent the user from setting the system
if a detector has lost contact with the control unit for
more than 15 minutes.
If a detector loses contact for more than two hours then
the control unit raises an alarm. The options available for
this alarm are:
With partition SET, the
control unit:
With partition UNSET
the control unit:
Fault Signals a supervision
fault to the ARC.
Displays an Alert and
sounds a fault tone.
Tamper Operates the siren and
signals a Tamper and
Supervision Fault to the
ARC.
Displays an Alert, sounds
the siren, and signals a
Tamper and Supervision
Fault to the ARC
Alarm Operates the siren and
signals an Alarm and
Supervision Fault to the
ARC.
Displays an Alert and
sounds a fault tone.